background image

Page 8 of 12 

Installation Notes 

 

Point the TX61U-IT solar panel toward the best 
available light source to recharge the batteries, but 
avoid a location in direct sun as it will cause incorrect 
temperature readings. We recommend facing the solar 
panel East to catch the early morning sun, and placing 
under an eave or overhang to avoid overhead sun. 

 

The TX61U-IT sensor uses internal rechargeable 
batteries to store the collected solar power. 

 

The sensor features a high-efficiency solar panel that 
maintains a full charge with minimal indirect light. 

Do 

not place in direct sun, as this will cause incorrect 
temp readings

 

Fog and mist will not harm the sensor but direct rain 
must be avoided.  

 

The TX61U-IT sensor has a wireless range of 200 feet 
(60.96 m).  Keep in mind that the 200 ft range equates 
to an open air scenario with no obstructions, and that 
radio waves DO NOT curve around objects. The actual 
transmission range will vary depending on the path of 
the signal. Each obstruction (roof, walls, floors, 
ceilings, thick trees, etc.) will effectively cut the signal 
range in half.   

 
Example

: If the TX61U-IT sensor, with a 200 feet 

(60.96 m) range, is mounted on an exterior wall, the 
signal must then pass through one exterior wall, one 
interior wall, and across the 10 feet (3 m) width of the 
room between the 2 walls to reach the wireless 
display.  The first wall will reduce the range to 100 feet 
(30.48 m), and the second wall will reduce the range to 
50 feet (15.24 m).  Factoring in the 10 foot room, this 
leaves a maximum of 40 feet (12. 2 m) of remaining 
signal range.   
 
This allowance is typically enough for a frame wall with 
non-metallic siding; however certain materials can 
reduce range even further.  Metal siding, stucco, and 
some types of glass can reduce signal range by as 
much as ¾ or more, compared to the ½ reduction 
typical of most obstructions.  It is possible to receive a 
signal through these materials, however maximum 
range will be much less due to their tendency to 
absorb or reflect a much larger portion of the sensor’s 
signal. 

 

The TX61U-IT sensor measures and transmits signal 
about every 8 seconds when its battery voltage is 
higher than 2.5V.   
 
Once the reset button is pressed on the TX-61U 
sensor and the batteries are inserted into the wireless 
display, the units will try to synchronize 
communication. If the wireless display fails to receive 

Summary of Contents for TX61U-IT

Page 1: ...less Weather Instruments by La Crosse Technology La Crosse Technology Ltd www lacrossetechnology com 2809 Losey Blvd S La Crosse WI 54601 Phone 608 782 1610 Table of Contents Table of Contents 1 Inven...

Page 2: ...s Display WWVB radio controlled time manual setting option available DST function on off selectable default is On Wireless outdoor temperature F or C Indoor temperature F or C Time alarm with 10 minut...

Page 3: ...low sufficient light to reach the solar panel while activating the sensor Make sure the lights are on in the setup room and the solar panel is facing a 60W light bulb or brighter do not cover with han...

Page 4: ...splay within 5 min remove the batteries from the display and go back to Step 1 make sure the batteries are fresh 4 Distance Between Units To ensure sufficient wireless communication the final distance...

Page 5: ...to select the desired Time zone setting 5 EST Eastern default setting 6 CST Central 7 MST Mountain 8 PST Pacific 9 ALA Alaska 10 11 12 12 11 10 9 8 7 6 5 4 3 2 1 Other time zones 0 Greenwich Mean Time...

Page 6: ...9 Set Date Day of Week Press the SET button a ninth time and the Day of Week abbreviation will flash Use the PLUS button to set the correct day of week 10 Set 12 or 24 Hour Time Mode Press the SET but...

Page 7: ...after 24 hours The alarm uses 3 different patterns of tone beginning gently and increasing in intensity known as a Crescendo Alarm Battery Replacement Information Wireless Display To replace the batt...

Page 8: ...half Example If the TX61U IT sensor with a 200 feet 60 96 m range is mounted on an exterior wall the signal must then pass through one exterior wall one interior wall and across the 10 feet 3 m width...

Page 9: ...and Other Mounting Options With the mounting bracket installed at the bottom or on the top of the TX61U IT sensor the user can place it on any flat surface IMPORTANT NOTE Before permanently attaching...

Page 10: ...s Do not submerge the unit in water Furthermore fix all parts in place where the units are adequately protected against moisture and rain Special care shall be taken when handling a damaged LCD displa...

Page 11: ...e presented upon request as proof of purchase to La Crosse Technology Ltd or La Crosse Technology Ltd s authorized service center La Crosse Technology Ltd will repair or replace this product at our op...

Page 12: ...fic legal rights You may also have other rights specific to your State Some States do not allow the exclusion of consequential or incidental damages therefore the above exclusion of limitation may not...

Reviews: