Temperature Trend Arrows 

 

Explanation:

 The indoor and outdoor temperature trend indicators will update every 30 minutes or less. 

These trends represent temperature changes over the past three hours. 
 

 

UP ARROW: Temperature rose more than 2°F /1°C in the past three hours 

 

RIGHT ARROW: Temperature has 

not changed

 more than 2°F /1°C in the past three hours  

 

DOWN ARROW: Temperature fell more than 2°F /1°C in the past three hours 

 

MIN/MAX Temperature readings 

 

Explanation:

 The temperature station shows the daily minimum and maximum temperatures each day 

starting at midnight (12:00 AM). The temperature station automatically resets the MIN/MAX temperatures 
at midnight (12:00 AM). 

  

 

View MIN data: 

Press and release the MIN TEMP button to view the minimum Indoor and Outdoor 

Temperatures.

   

 

Reset MIN data: 

Hold the MIN TEMP button for 5 seconds and the Indoor and all Outdoor Minimum 

Temperatures will reset. The temperature area will show dashes briefly then return to current 
temperatures.  

 

View MAX data: 

Press and release the MAX TEMP button to view the maximum Indoor and Outdoor 

Temperatures.

   

 

Reset MAX data: 

Hold the MAX TEMP button for 5 seconds and the Indoor and all Outdoor 

Maximum Temperatures will reset. The temperature area will show dashes briefly then return to 
current temperatures 

 

Mounting/Positioning Outdoor sensor 

 

First:

 Place the outdoor sensor in the desired shaded location and the temperature station in the home. 

Wait approximately 1 hour before permanently mounting the outdoor sensor to ensure that there is proper 
reception.  

 

POSITION 

  Mount outdoor temperature outdoor sensors 

vertically

.  

  Protect the outdoor sensor from standing rain or snow and from the overhead sun, which can cause it 

to read incorrectly.  

  Mounting under an eave or deck rail works well. 

  If you choose, you can construct a small roof or box for the outdoor sensor. Be sure a box has vents. 

  Mount the outdoor sensor on the North side where to prevent sun from causing incorrect readings.  

  Mount at least 6 feet in the air for a strong RF (radio frequency) signal. 

  Outdoor sensors are water resistant, not waterproof.  

  Avoid more than one wall between the outdoor sensor and the temperature station. 

  The maximum transmitting range in open air is over 300 feet (91 meters).  

  Obstacles such as walls, windows, stucco, concrete and large metal objects can reduce the range.  

  Do not mount near electrical wires, transmitting antennas or other items that will 

interfere 

with the 

signal. 

  RF (radio frequency) signals do not travel well through moisture or dirt. 

  Do not mount the outdoor sensor on a metal fence. This significantly reduces the effective

 range

. 

 

MOUNT 

Option 1: 

  Install one mounting screw (not included) into a wall. 

  Place the outdoor sensor onto the screw (hanging hole on the backside). 

  Gently pull down to lock the screw in place.  

 

Option 2:    

  Insert the mounting screw through the front of the outdoor sensor and into the wall.  

  Tighten the screw to snug (do not over tighten). 

 

Position Temperature Station 

 

  The temperature station has a wide base to sit on a desk or table.  

  Place withi

range 

of the outdoor sensor.  

Summary of Contents for T83639

Page 1: ...oor Temperature Reading 3 Intermittent Outdoor Temperature 3 Outdoor Temperature is stuck or HH H LL L 4 Outdoor sensor drains batteries quickly 4 Outdoor sensor fell The sensor no longer works 4 Temperature Trend Arrows 5 MIN MAX Temperature readings 5 Mounting Positioning Outdoor sensor 5 Position Temperature Station 5 Distance Resistance Interference 6 Temperature Alerts 6 Temperature Station 7...

Page 2: ...to an out of the box state and often resolves an issue Factory Restart 1 Remove all power from outdoor sensor and temperature station 2 Press one of the buttons on the temperature station at least 20 times to clear all memory 3 Verify that the temperature station is blank before proceeding there are some painted lines that will not disappear 4 Leave batteries out of both units for 15 minutes very ...

Page 3: ...connection between the outdoor sensor and the temperature station Turn the temperature station 90 degrees towards the outdoor sensor to provide better reception This allows more antenna surface to face the outdoor sensor signal Try the quick connect or factory restart Power Requirements 2 AA batteries power the outdoor sensor We recommend Alkaline batteries for the outdoor sensor You may choose to...

Page 4: ...t of alkaline batteries Write down the date of installation and the voltage of the batteries When the batteries fail please note the date and voltage again Check the distance and resistance between the outdoor sensor and temperature station Outdoor sensors at the end of the range may work while batteries are fresh but not after they drain a bit Check for leaking batteries which may damage the outd...

Page 5: ...station in the home Wait approximately 1 hour before permanently mounting the outdoor sensor to ensure that there is proper reception POSITION Mount outdoor temperature outdoor sensors vertically Protect the outdoor sensor from standing rain or snow and from the overhead sun which can cause it to read incorrectly Mounting under an eave or deck rail works well If you choose you can construct a smal...

Page 6: ... signal Do not mount the outdoor sensor on a metal fence This significantly reduces the effective range Interference Consider items in the signal path between the outdoor sensor and the temperature station Sometimes a simple relocation of the outdoor sensor or the temperature station will correct the interference Windows can reflect the radio signal Metal will absorb the RF radio frequency signal ...

Page 7: ...related issue Batteries may be overpowered or underpowered Remove batteries from the temperature station Press any button 20 times Leave the temperature station unpowered for 1 2 hours Install fresh Alkaline batteries with correct polarity If the indoor temperature is still shows dashes HH H or LL L the temperature station may need replacement Inaccurate Indoor Temperature Reading Explanation When...

Page 8: ... date Press the TIME DATE button to confirm and move to 12 24 hour time format 4 12 24 HOUR The time format 12H will flash use the ARROW buttons to choose 12 hour or 24 hour time format and press the TIME DATE button to confirm and move to hour 5 HOUR The Hour will flash use the ARROW buttons to choose the hour and press the TIME DATE button to confirm and move to minutes 6 MINUTES The Minutes wil...

Page 9: ...powered or underpowered Remove batteries from temperature station Press any button 20 times Leave the batteries out of the display for 2 hours Insert batteries into the temperature station Temperature station drains batteries quickly Test a new set of alkaline batteries Write down the date of installation and the voltage of the batteries When the batteries fail please note the date and voltage aga...

Reviews: