background image

The orifices are always replaced in the following sequence:

  Remove the back panel by unscrewing the screws that keep it in place.

  Screw the adjusting cone (2) and insert it into the mixing tube in order to free

sufficient space for unscrewing the orifice.

  Unscrew the orifice (1) with a 7 mm flat wrench.

  Install the orifice (1) corresponding to the new type of gas and tighten it.

  Ignite the burner and adjust the air inlet (see table page 3) by screwing or unscre-

wing the adjusting cone (2) until you obtain a slightly blue flame showing no
separation; separation of the flame is an indication that there is too much air. 

  Lock the adjusting cone (2) with the locking washer (3).

Once you have changed the injectors, it is a good idea to adjust the low settings for the
burner (see Section 2).

Save the orifices removed from the appliance for future use.

Note: Gas pressure regulator setting must also be adjusted when changing fuel
type.

Page  

4

4

M

Ma

aiin

ntte

en

na

an

nc

ce

e  M

Ma

an

nu

ua

all  B

Brro

oc

ch

he

e  F

Flla

am

mb

be

errg

ge

e

L

LA

A  C

CO

OR

RN

NU

UE

E

M

AINTENANCE

Fuel conversion

1

3

2

WARNING

The conversion kit shall be installed by a qualified servi-
ce agency in accordance with the manufacturer's ins-

tructions and all applicable codes and requirements of the autho-
rity having jurisdiction. If the information in these instructions is
not followed exactly, a fire, explosion or production of carbon
monoxide may result causing property damage, personal injury
or loss of life. The qualified service agency is responsible for the
proper installation of this kit. The installation is not proper and
complete until the operation of the converted appliance is chec-
ked as specified in the manufacturer's instructions supplied with
the kit.

Summary of Contents for Chateau series

Page 1: ...Flamberge R o t i s s e r i e C e n t e n a i r e B Y L A C O R N U E Maintenance m a n ua l C H Â T E A U S E R I E S L a C o r n u e 1 9 0 8 L a C o r n u e 2 0 0 8 1 9 0 8 ANSI CGA Standard Designation 85KJ ...

Page 2: ...nna K 08NOTMAINBFG100 UL 1 LA BROCHE FLAMBERGE GAS CONVERSION L LA A C CO OR RN NU UE E M Ma ai in nt te en na an nc ce e M Ma an nu ua al l B Br ro oc ch he e F Fl la am mb be er rg ge e Page 1 1 CONTENTS Read all instructions before using this appliance Save these instructions for future reference This book contains many important safety messages Always read and obey all safety messages ...

Page 3: ...actory to ensure optimum results Only the burner low flame setting can be adjusted by means of the following proce dure Remove the control knob by unscrewing the screw a using 3 mm allen Wrench that keeps him in position Remove the valve cover by unscrewing the screws b that keep it in place Re install the control knob of the burner ignite the burner then rotate the knob to its lowest setting 2 AD...

Page 4: ...rners The orifices size depends on the type of gas The table below is provided for you to determine which orifice should be used if the type of gas is changed 3 FUEL CONVERSION L LA A C CO OR RN NU UE E M Ma ai in nt te en na an nc ce e M Ma an nu ua al l B Br ro oc ch he e F Fl la am mb be er rg ge e Page 3 3 Adjustment of the low settings MAINTENANCE Adjustment of the burner lowest setting Knob ...

Page 5: ...tion 2 Save the orifices removed from the appliance for future use Note Gas pressure regulator setting must also be adjusted when changing fuel type Page 4 4 M Ma ai in nt te en na an nc ce e M Ma an nu ua al l B Br ro oc ch he e F Fl la am mb be er rg ge e L LA A C CO OR RN NU UE E MAINTENANCE Fuel conversion 1 3 2 WARNING The conversion kit shall be installed by a qualified servi ce agency in ac...

Page 6: ...Remove the valve cover by unscrewing the screws b see Section 2 that keep it in place The regulator is now accessible The regulator has a bayonet mounted top cap Using a small coin press in and turn the cap to remove it Turn the cap over so that the letters LP for propan gas or NAT for natural gas are visible on base of the hollow in the cap Replace the cap making sure that the bayonet pins are se...

Page 7: ...ray Company 185 Park Lane Brisbane CA 94005 USA Phone 800 892 4040 or 415 468 6620 Fax 415 468 0667 After sales Parts Service of 7 00 a m and 4 00 p m Pacific Time Monday through Friday excluding national Holidays by calling 877 LACORNUE Page 6 6 M Ma ai in nt te en na an nc ce e M Ma an nu ua al l B Br ro oc ch he e F Fl la am mb be er rg ge e L LA A C CO OR RN NU UE E MAINTENANCE Address IMPORTA...

Page 8: ...nt Z I les Béthunes 95310 Saint Ouen l Aumône FRANCE Postal address La Cornue SAS B P 99006 95070 Cergy Pontoise Cedex FRANCE Phone 33 0 1 34 48 36 36 Fax 33 0 1 34 64 32 65 E mail a table la cornue com w w w l a c o r n u e c o m L a C o r n u e 1 9 0 8 ...

Reviews: