Electrical
C
ONNECTIONS
metallic burr can enter the supply tube of the stove and block the burners. Then make
sure that all gas connections are properly sealed.
Refer to "Important Safety Information" section, on pages 1 - 8.
After all work has been completed on your gas supply network, an operating test must
be performed before connecting the Broche Flamberge, in order to ensure that no
metallic particles may enter the supply tube and obstruct the burner. The gas supply
piping system must be tested as shown in page 3 of this guide.
The appliance must be electrically installed and grounded in accordance with
local codes or in the absence of such codes with the latest edition of the
"National Electrical Code", ANSI/NFPA 70 in the USA, and CSA C22.2
"Canadian Electrical Code” - in Canada.
Disconnect all power supply circuits before accessing the junction boxes.
The Broche Flamberge is supplied with a connection terminal
block accessible by unscrewing the stainless steel protection plate
on the backside.
This appliance must be supplied with 120 Volt and 60 Hz frequency,
and connected to an individual, properly grounded branch circuit,
protected by a circuit breaker or time-delay fuse. Circuit Breaker
size chosen to meet local codes according to max electrical power of
15.5 Watts (0.13 Amps).
Wiring must conform to National Electric Codes.
If the electric service provided does not meet the above specifications, have a licensed
electrician install an approved outlet.
Because rotisserie terminals are not accessible after appliance is in position, flexible
service conduit or cord must be used. The appliance can then be easily disconnected for
servicing.
R
EMINDER
: connection to the general power supply must be via terminal blocks
(preferably of the self-shearing type), not by means of plugs.
Fix the cable way below the hot air outlets, at the back of the Broche Flamberge, never in
front of them.
1. E
LECTRICAL CONNECTIONS
C
O N N E C T I O N S
L
LA
A C
CO
OR
RN
NU
UE
E
IIn
ns
stta
alllla
attiio
on
n g
gu
uiid
de
e B
Brro
oc
ch
he
e F
Flla
am
mb
be
errg
ge
e
Page
1
15
5
G N
Ph
120 V a.c. / single phase
G-Ground = Green
N-Neutral = White
Ph-Phase (Hot) = Black