9.2 Selections Programming - Cofffee / Cappuccino
9.2.1)
Press one of the coffee selection
keys. The following message will
be displayed (in case of
"personalization selections" =
NO):
The arrow
will appear on the line „1 MM1 Coffee“ if the „Selections
Personalization“ function (Paragraph 7.2.4) is activated (
YES
). To go
to line „Water dose 100“, press the „"
"""
"key (
31
).
Press the „+“ and „-“ keys (
30
) to change the water dose (volumetric
counter pulses from „
10
“ to „
1000
“ at „
1
“-step pulses).
!
Selection 07
1 coffee MM1
Water dose 100
Coffee dose 1 3,2
!
9.2.2)
Press key"
"""
" (
31
) to move
to the line below. The following
message will be displayed:
Selection 07
1 coffee MM1
Water dose 100
Coffee dose 1 3,2
!
Press the „+“ and „-“ keys (
30
) to change the coffee dose 1 (grind time
associated to grinder1, from „
0.0
“ to „
12.0
“ at "
0.1"
second steps.
9.2.2a)
Press key"
"""
" (
31
) to move
to the line below. The following
message will be displayed:
Selection 07
1 coffee MM1
Coffee dose 1 3,2
Coffee dose 2 1,7
!
Press the „+“ and „-“ keys (
30
) to change the coffee dose 2 (grind time
associated to grinder 2, „Ms“ blend skip function, from „
0.0
“ to „
12.0
“
at "
0.1
"second steps.
11. Special Functions
SECOND BLEND (Ms) Function (only for double doser-grinder
machines)
Enables withdrawal of coffee using doser-grinder „2“ for all drinks
associated with
doser-grinder „1“ (MM1).
When the second blend key is pressed, all the leds associated to doser-
grinder „1“ will flash.
When one of the dispensing keys corresponding to the desired dose is
pressed, grinding is made by doser-grinder „2“ while all the set
parameters remain unchanged, excluding the parameter corresponding
to the coffee dose (grinding time).
N.B. Before dispensing, press key (Ms) again to stop the „second
blend“ operation.
The SECOND MILK (M) function (valid only for M52 STATION
machines)
This function dispenses the milk from container „2“ for all drinks
associated to milk container „1“.
When the „secondd milk“ key is pressed, all leds of all the keys
associated to milk container „1“ flash.
When one of the dispensing keys corresponding to the desired dose is
pressed, milk is dispensed by container „2“ while all the set parameters
remain unchanged.
N.B. Before dispensing, press key (M) again to stop the „second milk“
operation.