3.FUNCTIONING
LIGHTING AND COMBUSTION
If, during the first lighting, the stove should emanate smells due to the evaporation of
substances used in the manufacturing, it is sufficient to ventilate the room for a few hours.
Use small and medium-size logs and put them in the fireplace so that the air can penetrate
between them. Place at the base of the stack some lighters (we recommend tablet derived
from natural wax).
With the air regulation register you can regulate the passage of primary and secundary air,
necessary for combustion. While lighting the stove the register shall be totally opened.
This register is placed:
•
In the stoves with ash drawer, on the same drawer;
•
In the stoves with “Great Fire Door”, there’s a knob at the base of the stove.
The use will be as follows:
-
To light the stove: air register completely opened
-
For a medium combustion: air register half opened
-
For slow combustion: air register opened 1/3
These positions can be changed in relation to the chimney draft.
ADVICE: do not close the register completely because by doing so the combustion would be
deprived of the necessary air, giving rise to a choked combustion and to the growing of soot
on the door glass.
AIR REGULATION