2.0  DESCRIPTION OF CONTROLS 

 

 

 

 

 

 

 

2.1 

BYPASS

 switch

 

 

Pressing  BYPASS  cancels  gating  by  removing  the  side  chain  voltage  from  the 

voltage  controlled  amplifier  (VCA).  The  Input-Output  and  level  change  circuitry 

remain in the signal path. 

 

The BYPASS led lights when the compressor is Bypassed. 

 

 

  

2.2 

LISTEN

 switch

 

 

This  facility  allows  the  side  chain  signal  to  be  monitored  at  the  channel  output. 

This is useful for tuning the side chain filters by ear. 

 

 

 

2.3 

HI-PASS

 control

 

 

This  control  sets  the  cut  off  frequency  of  the  high  pass  filter  in  the  side  chain 

signal  path.  Side  chain  signals  at  frequencies  below  the  cut  off  frequency  are 

attenuated and so will not operate the gate. 

 

Use this control to prevent low frequency signals, such as a miked up bass drum, 

opening the gate. 

 

 

 

2.4 

LO-PASS

 control

 

 

This control sets the cut off frequency of the low pass filter in the side chain signal 

path.  Side  chain  signals  at  frequencies  above  the  cut  off  frequency  are 

attenuated and so will not operate the gate. 

 

Use this control to prevent high frequency signals, such as a miked up hi-hat 

cymbal, opening the gate. 

 

 

 

Please note: 

The  filters  are  always  in  the  side  chain  signal  path  so  if  not  required  it  is 

necessary  to  set  the  controls  to  their  extreme  frequencies  to  prevent  them 

affecting the side chain signal.

 

 

 

 

Summary of Contents for G400

Page 1: ...4 Channel Frequency Conscious Noise Gate Operation Manual June 2005 ...

Page 2: ...Page 2 This page has been left intentionally blank for your notes ...

Page 3: ...Attack switch 2 9 Range switch 2 10 Release control 2 11 Link switch 3 0 EXTERNAL CONNECTIONS 8 9 3 1 Side Chain insert 3 2 Input 3 3 Output 3 4 Level switch 3 5 Power switch 3 6 Power inlet 4 0 INSTALLATION 10 11 4 1 Inspection and unpacking Phantom 4 2 Operating Environment 48V indicator 4 3 CE Standard and LVD Pad 4 4 Power Requirement Listen 5 0 WARRANTY 12 6 0 TECHNICAL SPECIFICATION 13 7 0 D...

Page 4: ...ully variable controls for filter Frequency Threshold and Release Range is switchable to provide either full muting 80dBu or a more subtle level of signal attenuation 20dBu Two Attack modes are available Fast or Slow and Release is manually adjustable In built sidechain auto level sensing and Hold circuitry ensure that false triggering and chatter are kept to a minimum High and Low pass filters ar...

Page 5: ...in signal path Side chain signals at frequencies below the cut off frequency are attenuated and so will not operate the gate Use this control to prevent low frequency signals such as a miked up bass drum opening the gate 2 4 LO PASS control This control sets the cut off frequency of the low pass filter in the side chain signal path Side chain signals at frequencies above the cut off frequency are ...

Page 6: ...s These two leds indicate the relationship between the side chain signal which is normally the same as the input signal unless the side chain insert is used and the THRESHOLD setting The BELOW led indicates that the signal level is below threshold and the gate is closed In practise when the BELOW led lights the audio starts to fade at a rate set by the RELEASE control The ABOVE led indicates that ...

Page 7: ... set by the THRESHOLD control Control range is 10mS to 4S Please note With instruments such as bass guitars short RELEASE times can cause the gate to chatter If this occurs increase the release time 2 11 LINK switch Pressing the LINK switch couples channels 1 2 and 3 4 for stereo operation Channels 1 and 3 become the masters the controls on channels 2 and 4 are disabled The side chain circuitry on...

Page 8: ...3 2 INPUT Electronically balanced Input with pin 2 wired hot signal Unbalanced operation is possible by joining pin 3 to pin 1 signal ground and using pin 2 as signal hot Please note To maintain correct signal levels in un balanced applications pin 3 must be joined to pin 1 and not left un connected 3 3 OUTPUT Electronically balanced Output with pin 2 wired hot signal For un balanced operation pin...

Page 9: ...ER INLET Standard IEC mains inlet for use with a detachable mains cable See Section 3 4 for details of power requirements and fusing Please note The mains protection fuse is inside the unit accessed by removing the top cover Ensure that the unit is disconnected from the mains supply before attempting to replace the fuse ...

Page 10: ...vels 4 3 CE STANDARDS AND THE LOW VOLTAGE DIRECTIVE LVD The G400 has been designed to comply with the latest Electromagnetic Compatibility EMC regulations However we recommend you do not operate the unit close to strong emitters of electromagnetic radiation such as power transformers motors mobile telephones or radio transmitters The unit should only be connected to a power supply of the type desc...

Page 11: ...nd may constitute a fire hazard The detachable IEC mains lead connections to the appliance are coloured in accordance with the following code Green and Yellow Earth Blue Neutral Brown Live WARNING THIS APPLIANCE MUST BE EARTHED Please note A protective earth connection made by way of the earth conductor in the power cord is essential for safe operation ...

Page 12: ...cessary to return the unit to an LA Audio authorised service centre or to the factory with a dated receipt as proof of purchase After repair the unit will be returned to you free of charge Limitations This warranty does not cover damage resulting from accident or misuse The warranty is void unless repairs are carried out by an authorised service centre The warranty is void if the unit has been mod...

Page 13: ...z 22kHz Threshold 50dB to 20dB Range 80dB or 20dB Attack Fast 50uS Slow 1mS Release 10ms to 4s variable High Pass Filter 22Hz to 3kHz Low Pass Filter 250Hz to 30kHz Power Requirement 15VA 115 230V AC 50 60Hz PHYSICAL Input Connectors XLR 3 pin Pin 2 hot Output Connectors XLR 3 pin Pin 2 hot Power Connection IEC 3 pin socket Detachable lead Dimensions mm 482 19 W 164 6 5 D 44 1 75 H Weight 2 9 kg 6...

Page 14: ...ge 14 7 0 DIMENSIONS In keeping with our policy of continuous improvement LA Audio reserves the right to alter specifications without prior notice Manufactured in the UK by LA Audio Web www laaudio co uk ...

Reviews:

Related manuals for G400