TROUBLESHOOTING

VI. 

Troubleshooting

Symptom

Possible

Solution

Power not "ON"

Bad power connection

Check external power adapter

LINK/RVC not 

"ON"

- Wrong connection switch
- Bad connection

- Check Connection switch setting
- Check patch cord

COL LED

Wrong termination setting

Check Terminator setting
Check coaxial

Summary of Contents for LCTP-10BT-10B2

Page 1: ...North Andover MA 01845 www L com com E mail sales L com com Phone 1 800 343 1455 Fax 1 978 689 9484 L com Inc All Rights Reserved L com Global Connectivity and the L com logo are registered marks 10Ba...

Page 2: ...structions may cause harmful interference in which case the user will be required to correct the interference at user s own expense Due to the confidence of the quality of our products we are now exte...

Page 3: ...ne 1 800 343 1455 Fax 1 978 689 9484 L com Inc All Rights Reserved L com Global Connectivity and the L com logo are registered marks CONTENTS I Overview 1 II Thin Ethernet Termination Switch 2 III 10B...

Page 4: ...marks 1 OVERVIEW This booklet is designed as a guide for the easy installation of 10Base 2 to 10Base T Converter The 10Base 2 T Converter is designed to connect an existing 10Base 2 Thin Ethernet ada...

Page 5: ...ll Rights Reserved L com Global Connectivity and the L com logo are registered marks 2 SWITCH ON Set the terminator to the ON Position when the converter is placed at the end of the segment See set up...

Page 6: ...the W S position for a Workstation connection 1 TX 2 TX 3 RX 6 RX III Connection Switch L com Inc 50 High St West Mill 3rd Floor Suite 30 North Andover MA 01845 www L com com E mail sales L com com Ph...

Page 7: ...lision indicators blinks when data collision occurs at either the 10Base T or 10Base 2 Port LINK RCV With this indicator ON data link is operating and converter is ready to receive data When this indi...

Page 8: ...e into BNC connector V Set Up Procedures 10Base 2 Connection RJ 45 Converter BNC Connectors Coaxial Cable To 10Base T Hub or Workstation Converter BNC Connectors Coaxial Cable RJ 45 To 10Base T Hub or...

Page 9: ...e T Connection Converter BNC Connectors Hub Thin Ethernet Coaxial Cable Unshielded Twisted Pair Cable BNC Connectors Converter Workstation RJ 45 Thin Ethernet Coaxial Cable Unshielded Twisted Pair Cab...

Page 10: ...erved L com Global Connectivity and the L com logo are registered marks 7 TROUBLESHOOTING VI Troubleshooting Symptom Possible Solution Power not ON Bad power connection Check external power adapter LI...

Page 11: ...emperature Humidity Dimensions Power Adapter EMI IEEE 802 3 10 Base T 10Base 2 standards BNC connector for thin Ethernet RJ 45 Jack for 10Base T Ethernet RG 58 coaxial cable for thin Ethernet connecti...

Reviews: