Installation 

This chapter gives step-by-step installation instructions for the Converter. 
 

Selecting a Site for the Equipment 

As with any electric device, you should place the equipment where it will not be 
subjected to extreme temperatures, humidity, or electromagnetic interference. 
Specifically, the site you select should meet the following requirements: 
 

y

 

The ambient temperature should be between -40 to 75 degrees Celsius. 

y

 

The relative humidity should be less than 95 percent, non-condensing. 

y

 

Surrounding electrical devices should not exceed the electromagnetic field (RFC) 

standards. 

y

 

Make sure that the equipment receives adequate ventilation. Do not block the 

ventilation holes of the equipment. 

y

 

The power outlet should be within 1.8 meters of the product. 

 

DIN Rail Mounting 

Fix the DIN rail attachment plate to the back panel of the media converter. 
 
Installation: Place the media converter on the DIN rail from above using the slot. 
Push the front of the media converter toward the mounting surface until it audibly 
snaps into place. 
 
Removal: Pull out the lower edge and then remove the media converter from the DIN 
rail. 
 

 

 

Summary of Contents for L-EL9000

Page 1: ...wo pairs of power inputs can be used to power up this media converter Redundant power supplies function is supported You need to have two power inputs connected to run the media converter but the FAUL...

Page 2: ...sts the pinouts of 1000Base T port The 1000BaseSX LX Connections The fiber port pinouts The Tx transmit port of device I is connected to the Rx receive port of device II and the Rx receive port of dev...

Page 3: ...ff Steady A valid network connection established for copper port LNK stands for LINK LNKC Off No valid network connection established for copper port Steady A valid network connection established for...

Page 4: ...o 75 40 to 167 operating temperature range Tested for functional operation 40 to 85 40 to 185 UL1604 Industrial Control Equipment certified Maximum Surrounding Air Temperature 74 165 y Supports DIN Ra...

Page 5: ...Hardened Media Converter 5...

Page 6: ...y Solution The hardened media converter is a plug and play compact media converter which doesn t have any complicated software to set up This manual describes the installation and use of the hardened...

Page 7: ...TUP AND DISMANTLING 4 Preface 6 Table of Contents 7 Introduction 8 PRODUCT OVERVIEW 8 PRODUCT FEATURES 8 PACKING LIST 9 One Channel Media Converter 10 PORTS 10 PORT SETTINGS 10 DIP SWITCH 10 FRONT PAN...

Page 8: ...ets IEC61000 6 2 EMC Generic Standard Immunity for industrial environment y Support 802 3ab 802 3z 802 3x Auto negotiation and Auto MDI MDIX y 1000Base SX LX Multi mode Single mode or WDM Single mode...

Page 9: ...2 Groups A B C and D OR non hazardous locations only y WARNING EXPLOSION HAZARD Do not disconnect equipment unless power has been removed or the area is known to be non hazardous y WARNING EXPLOSION H...

Page 10: ...ns of a DIP Dual Inline Package switch on the front panel of the hardened media converter Default DIP switch settings 1 2 3 4 1 0 DIP Switch There are four pins on the DIP switch for port settings Ref...

Page 11: ...stands for POWER PWR1 PWR2 Off Power off Steady A valid network connection established for copper port LNK stands for LINK LNKC Off No valid network connection established for copper port Steady A va...

Page 12: ...should be less than 95 percent non condensing y Surrounding electrical devices should not exceed the electromagnetic field RFC standards y Make sure that the equipment receives adequate ventilation Do...

Page 13: ...k Power Inputs There are two pairs of power inputs can be used to power up this device You need to have two power inputs connected to run the media converter but the FAULT LED indicator will light up...

Page 14: ...that are used for power failure detection It provides a normal closed output when the power source is active Use this as a dry contact application to send a signal for power failure detection Special...

Page 15: ...Max Current Consumption 0 76A 12VDC 0 38A 24VDC 0 19A 48VDC Power Consumption 9 12W Max Operating Temperature 40 C 75 C 40 167 Tested for functional operation 40 C 85 C 40 185 UL1604 Industrial Contro...

Page 16: ...Hardened Media Converter 16 NEMA TS1 2 Environmental requirements for traffic control equipment...

Reviews: