background image

Attention 

Read and understand this manual 

before assembling, starting or 

servicing the heater. Improper use 

of heater can cause serious injury.

Keep this manual for future  

reference.

FOR PROFESSIONAL USE ONLY

www.lbwhite.com

SCAN THIS

with your smartphone or

visit https://bit.ly/3qjEEkw to  

view maintenance videos  

for L.B.White heaters.

WORLD PROVIDER - INNOVATIVE CLIMATE SOLUTIONS

411 Mason Street, Onalaska, WI 54650  •  800-345-7200  •  608-783-5691  •  608-783-6115 (fax)  •  www.lbwhite.com

Volt

™ 

40 

Electric Fan Heater

CE040

40kW

Owner’s Manual and Instructions

View this manual online at www.lbwhite.com

*  Requires an app like QR Droid 

for Android or for iPhone

The herein installation instructions are the L.B. White Co. LLC 

suggested recommendations and guidelines for temporary or 

permanent installation of the L.B. White Co. LLC heaters. Local, 

state, and electrical and safety code requirements supersede these 

guidelines.

Congratulations!

You have purchased the finest agricultural building heater available. 

 

Your new L.B. White heater incorporates the benefits from the most experienced 

 

manufacturer of heating products using state-of-the-art technology. 

We, at L.B. White, thank you for your confidence in our products and welcome 

 

any suggestions or comments you may have...contact us at 1-(800)-345-7200,  
or email us at [email protected].

NOTICE

Summary of Contents for Volt 40

Page 1: ...line at www lbwhite com Requires an app like QR Droid for Android or for iPhone The herein installation instructions are the L B White Co LLC suggested recommendations and guidelines for temporary or permanent installation of the L B White Co LLC heaters Local state and electrical and safety code requirements supersede these guidelines Congratulations You have purchased the finest agricultural bui...

Page 2: ...CONNECT TO PROPERLY GROUNDED OUTLETS ONLY DO NOT INSERT OR ALLOW FOREIGN OBJECTS TO ENTER ANY VENTILATION OR EXHAUST OPENING AS THIS MAY CAUSE AN ELECTRIC SHOCK OR FIRE OR DAMAGE THE HEATER TO PREVENT A POSSIBLE FIRE DO NOT BLOCK AIR INTAKES OR EXHAUST IN ANY MANNER DO NOT USE ON SOFT SURFACES WHERE OPENINGS MAY BECOME BLOCKED A HEATER HAS HOT AND ARCING OR SPARKING PARTS INSIDE DO NOT USE IN AREA...

Page 3: ...on Volt 40 Power kW 40 Maximum Output per Hour BTU H 2 Stage Selector 51 200 102 400 136 500 Airflow CFM 1 765 Electrical Connection VAC Hz Phase 480 60 3 Amperage Draw A Partial 20 Partial 40 Full 50 Ambient Thermostat Temperature Range 32 100 F 0 40 C Length in 46 0 Width in 20 0 Height in 25 0 Weight lbs 125 0 Keep the heater clean of dust at any time Dust may cause fire when heated Make sure t...

Page 4: ...arked S1 S2 and S3 S1 ON Partial output 16 kW 51 200 BTU h S1 S2 ON Partial output 32 kW 102 400 BTU h S1 S2 S3 ON Full output 40 kW 136 500 BTU h THE HEATER WILL NOW OPERATE AUTOMATICALLY CONTROLLED BY THE THERMOSTATS TO STOP HEATING 1 Turn the main switch into position OFF standby 2 Let the fan run until it stops automatically do not disconnect heater from power source 3 Disconnect the power sup...

Page 5: ... Toggle switch for 16kW output S3 Toggle switch for 8kW output TA Ambient Thermostat TC Cooldown thermostat TO 1 Overheat limit switch inner TO 2 Overheat limit switch discharge TR Transformer 480V 24 V AC X1 Terminal Block Manual Rev Changes Date Rev Revision Change Description 9 12 2022 A No Released 4 6 2023 B Yes UL requirement of Hyperthermia statements added 5 11 2023 B No Updated Outer Cove...

Page 6: ...ist Volt 40 Chassis Item Description Part 1 Outer Cover White Incl Connection Hatch w Labels 474372 1 Outer Cover Green Incl Connection Hatch w Labels 474372G 2 Handle 474371 3 Overheat Limit Switch Inner 474337 4 Cooldown Thermostat 474336 5 Overheat Limit Switch Air Outlet 474334 6 Wheel 474364 7 Locking Washer 474365 8 Heating Element 15 per heater 474361 9 Guard Ring 474354 ...

Page 7: ... Auxillary Contact 474338 13 Strain Reliever 474355 14 Toggle Switch 474343 15 Fuse Holder 474376 Fuse 474376A 16 Terminal Block 474349 17 Transformer 474344 18 Locking Clamp 2 Heater 474350 19 Plastic Bracket 474358 20 Ambient Thermostat 474333 21 Thermostat Knob 474335 22 Fan Motor 474326 23 Fan Blade 474330 Parts List Volt 40 Fan Enclosure 10 11 11 11 13 14 15 16 17 18 19 20 21 22 23 12 ...

Page 8: ...ip for 12 months from the date of purchase by the end user Warranty is automatic if a component is found defective within 12 months of the date code marked on the part If the defect occurs more than 12 months later than the date code but within 12 months from the date of purchase by the end user a copy of a bill of sale will be required to establish warranty qualification The warranty set forth ab...

Page 9: ...nes Vea este manual en línea en www lbwhite com Requiere una aplicación como QR Droid para Android o para iPhone Las instrucciones de instalación aquí contenidas son las de L B White Co LLC sugirió recomendaciones y pautas para la insta lación temporal o permanente de L B Calentadores White Co LLC Los requisitos de los códigos eléctricos y de seguridad locales estatales y estatales reemplazan esta...

Page 10: ... CORRIENTE CONÉCTELO SOLO A TOMACORRIENTES CON CONEXIÓN A TIERRA NO INTRODUZCA NI PERMITA QUE SE INTRODUZCAN OBJETOS EXTRAÑOS EN NINGUNAABERTURA DE ENTRADA O SALIDA YA QUE ESTO PUEDE CAUSAR UNA DESCARGA ELÉCTRICA O UN INCENDIO O DAÑAR EL CALEFACTOR PARA EVITAR UN POSIBLE INCENDIO NO BLOQUEE DE NINGUNA MANERA LAS ENTRADAS O SALIDAS DE AIRE NO LO UTILICE EN SUPERFICIES BLANDAS DONDE LAS ABERTURAS SE...

Page 11: ...e el ventilador los refrigera eficazmente los elementos calefactores tienen temperaturas superficiales elevadas Por ello se debe mantener los materiales combustibles a una distancia segura del calefactor y se debe tener cuidado de que no entren partículas combustibles en el calefactor con el aire aspirado por el ventilador Información general Mantenga el calefactor libre de polvo en todo momento E...

Page 12: ... POR LOS TERMOSTATOS APAGADO DE LA CALEFACCIÓN 1 Coloque el interruptor principal en la posición OFF en espera 2 Permita que el ventilador funcione hasta que se detenga automáticamente no desconecte el calefactor de la fuente de alimentación 3 Desconecte el enchufe del cable de alimentación NOTA EL CALEFACTOR ESTÁ EQUIPADO CON UN INTERRUPTOR DE LÍMITE DE SOBRECALENTAMIENTO QUE PUEDE HACER APAGAR E...

Page 13: ... Elemento calefactor S1 Interruptor de palanca para una potencia de 16 kW S2 Interruptor de palanca para una potencia de 16 kW S3 Interruptor de palanca para una potencia de 8 kW TA Termostato de ambiente TC Termostato de enfriado TO 1 Interruptor de límite de sobrecalentamiento interior TO 2 Interruptor de límite de sobrecalentamiento descarga TR Transformador 480 V 24 V CA X1 Bloque de terminale...

Page 14: ...pción N de pieza 1 Cubierta exterior blanca Incl Compuerta de conexión con etiquetas 474372 1 Cubierta exterior verde Incl Compuerta de conexión con etiquetas 474372G 2 Asa 474371 3 Interruptor de límite de sobrecalentamiento interior 474337 4 Termostato de enfriado 474336 5 Interruptor de límite de sobrecalentamiento salida de aire 474334 6 Rueda 474364 7 Arandela de bloqueo 474365 8 Elemento cal...

Page 15: ... auxiliar 474338 13 Aliviador de tensión 474355 14 Interruptor de palanca 474343 15 Fusible portafusible 474376 16 Bloque de terminales 474349 17 Transformador 474344 18 Abrazadera de sujeción 2 calefactor 474350 19 Soporte plástico 474358 20 Termostato de ambiente 474333 21 Perilla del termostato 474335 22 Motor del ventilador 474326 23 Aspa del ventilador 474330 Lista de piezas Volt 40 Recinto d...

Page 16: ...ir de la fecha de compra por parte del usuario final La garantía es automática si un componente se encuentra defectuoso dentro de los 12 meses siguientes al código de fecha marcado en la pieza Si el defecto se produce luego de los 12 meses de dicho código de fecha pero dentro de los 12 meses siguientes a la fecha de compra por parte del usuario final se requerirá una copia de la factura de venta p...

Reviews: