Propane ggas aand nnatural ggas hhave m

man-m

made oodorants aadded sspecifically ffor ddetection oof ffuel ggas lleaks.

If aa ggas lleak ooccurs, yyou sshould bbe aable tto ssmell tthe ffuel ggas.  

THAT’S  YYOUR  S

SIGNAL  TTO  G

GO  IINTO  IIMMEDIATE  AACTION!

Do not take any action that could ignite the fuel gas.  Do

not operate any electrical switches.  Do not pull any

power supply or extension cords.  Do not light matches

or any other source of flame.  Do not use your

telephone.

Get everyone out of the building and away from the area

immediately.

Close all propane gas tank or cylinder fuel supply

valves.

Propane gas is heavier than air and may settle in low

areas.  When you have reason to suspect a propane

leak, keep out of all low areas.  

Use your neighbor’s phone and call your fuel gas

supplier and your fire department.  Do not re-enter the

building or area.

Stay out of the building and away from the area until

declared safe by the firefighters and your fuel gas

supplier.

FINALLY,  let the fuel gas service person and the

firefighters check for escaped gas.  Have them air out

the building and area before you return.  Properly

trained service people must repair the leak, check for

further leakages, and then relight the appliance for you.

WARNING

Do not use this heater for heating human living

quarters.

Do not use in unventilated areas.

The flow of combustion and ventilation air must not be

obstructed.

Proper ventilation air must be provided to support the

combustion air requirements of the heater being used.

Refer to the specification section of the heater’s

Owner’s Manual, heater dataplate, or contact the L.B.

White Company to determine combustion air ventilation

requirements of the heater.

Lack of proper ventilation air will lead to improper

combustion.

Improper combustion can lead to carbon monoxide

poisoning leading to serious injury or death.  Symptoms

of carbon monoxide poisoning can include headaches,

dizziness and difficulty in breathing.

Asphyxiation H

Hazard

Some  ppeople  ccannot  ssmell  w

well.    S

Some  ppeople  ccannot

smell  tthe  oodor  oof  tthe  m

man-m

made  cchemical  aadded  tto

propane.    YYou  m

must  ddetermine  iif  yyou  ccan  ssmell  tthe

odorant iin tthese ffuel ggases.  

Learn to recognize the odor of propane gas.  Local

propane gas dealers will be more than happy to give

you a “scratch and sniff” pamphlet.  Use it to become

familiar with the fuel gas odor.  

Smoking can decrease your ability to smell.  Being

around an odor for a period of time can affect your

sensitivity to that particular odor.

The  oodorant  iin  ppropane  ggas  iis  ccolorless  aand  tthe

intensity  oof  iits  oodor  ccan  ffade  uunder  ssome

circumstances.

If there is an underground leak, the movement of gas

through the soil can filter the odorant.  

Propane gas odor may differ in intensity at different

levels.  Since propane gas is heavier than air, there may

be more odor at lower levels.

Always  bbe  ssensitive  tto  tthe  sslightest  ggas  oodor. If you

continue to detect any gas odor, no matter how small,

treat it as a serious leak.  Immediately go into action as

discussed previously.

Safety Precautions

FUEL GAS ODOR

ODOR FADING -- NO ODOR DETECTED

ATTENTION -- CRITICAL POINTS TO REMEMBER!

Propane gas has a distinctive odor.  Learn to recognize

these odors.  (Reference Fuel Gas Odor and Odor

Fading sections above.

If you have not been properly trained in repair and service

of propane gas fueled heaters, then do not attempt to

light heater, perform service or repairs, or make any

adjustments to the heater on propane gas.

Even if you are not properly trained in the service and

repair of the heater, ALWAYS be consciously aware of

the odors of propane gas.

A periodic “sniff test” around the heater or at the

heater’s joints; i.e. hose, connections, etc., is a good

safety practice under any conditions.  If you smell even

a small amount of gas, CONTACT YOUR FUEL GAS

SUPPLIER IMMEDIATELY.  DO NOT WAIT!

5

Summary of Contents for Tradesman CP100

Page 1: ...nts you may have call us toll free at 1 800 345 7200 Owner s Manual and Instructions Tradesman Construction Heater ATTENTION ALL USERS This heater has been tested and evaluated by CSA International in...

Page 2: ......

Page 3: ...n lead to property damage personal injury or loss of life GENERAL HAZARD WARNING Failure to comply with the precautions and instructions provided with this heater can result in Death Serious bodily in...

Page 4: ...tor or the L B White Co Inc for assistance or if you have any questions about the use of the equipment or its application The L B White Co Inc has a policy of continuous product improvement It reserve...

Page 5: ...pping Weight lbs Electrical Supply Volts Hz Phase Amp Draw Dimensions Inches L x W x H Minimum Safe Distances From Nearest Combustible Materials Minimum Ambient Temperature In Which Heater May Be Oper...

Page 6: ...ous injury or death Symptoms of carbon monoxide poisoning can include headaches dizziness and difficulty in breathing Asphyxiation H Hazard Some p people c cannot s smell w well S Some p people c cann...

Page 7: ...backflash switch Never operate this heater with any safety device that has been bypassed Do not operate this heater unless all of these features are fully functioning 7 Do not operate the heater with...

Page 8: ...on heater or within owner s manual 8 This heater is provided with a pre set single stage regulator and a gas hose as specified by L B White Co of proper length diameter and construction Make sure thes...

Page 9: ...all connections securely 4 Check a all c connections f for g gas l leaks u using a approved gas l leak d detectors HOSE AND REGULATOR ASSEMBLY FIG 2 1 Fasten the carrying handle to the heater case to...

Page 10: ...input rating stamped on the dataplate of the heater Do not use an orifice size different than specified for the input rating of this heater fuel type configuration and altitude FIG 3 If the heater is...

Page 11: ...VALVE 2 The valve can be adjusted to deliver either minimum heat or maximum heat When the valve handle is parallel to the gas flow the valve is completely open to deliver maximum heat output Refer to...

Page 12: ...condition of the heater before each use to determine if a general cleaning is necessary a Use compressed air or a soft brush to clean interior and exterior surfaces and component parts of dust and di...

Page 13: ...vice Instructions MOTOR AND FAN ASSEMBLY THERMOCOUPLE CAUTION Allow the heater to cool before servicing BURNER PLATE THERMOCOUPLE CLIP 1 2 INCH 1 Disconnect the heater from its electrical supply and c...

Page 14: ...FLAT ORIFICE BURNER PLATE RING BOWED MANIFOLD IGNITER BURNER PLATE 1 8 1 Disconnect the heater from its electrical supply and close all fuel supply valves to the inlet of the heater 2 Remove the case...

Page 15: ...e case top 7 Reconnect the heater to its electrical supply and open all fuel supply valves to the heater 8 Start the heater and check for proper operation FIG 10 CAP SAFETY CONTROLVALVE LOW PRESSURE G...

Page 16: ...n the backside of the switch Be careful not to melt the switch housing when testing 3 Within thirty seconds you should here a pop coming from the switch indicating that the electrical contacts have op...

Page 17: ...ctively use these flow charts you must first identify the problem The problems are numbered sequentially along with a brief explanation of each problem Start at the diamond closest to the identified p...

Page 18: ...air or Replace as Necessary Yes No Yes Yes Replace Power Cord Is Proper Voltage Supplied to heater A Check Circuit Breakers B Check for Proper Length and Gauge of Extension Cord if used C Contact a qu...

Page 19: ...e Heater See Dataplate Provide Proper Gas Pressure to Heater Inlet Check High Voltage Lead for Continuity Replace if Necessary Check Igniter Gap Gap is 1 8 in Reposition the Igniter Plugged Burner Ori...

Page 20: ...k Determine Cause of Backflash Switch Opening See Problem 5 No Have Individual Wires Been Checked from thermocouple Energy Cut Off to Relay and Backflash Switch Check Individual Wires for Continuity N...

Page 21: ...hten the Set Screw Yes No Yes Yes Is Heater Receiving Proper Ventilation Increase Room Ventilation or Reposition Heater to Avoid Recirculation of Hot Air Bend Switch Mounting Bracket Away from Burner...

Page 22: ...TRICAL CONNECTION DIAGRAM WARNING THIS HEATER MAY START AT ANYTIME CAUTION REFERTOTHE HEATER S ELECTRICAL CONNECTION DIAGRAMWHEN SERVICINGTO AVOIDWIRING ERRORS AND HEATER MALFUNCTION CHECK FOR PROPER...

Page 23: ...used on automatic spark ignition control systems Ignites gas by spark Motor Converts electrical energy into mechanical energy It is used in conjunction with the fan blade to pull air into the burner f...

Page 24: ...Parts Identification PARTS SCHEMATIC 33 32 31 29 28 30 27 26 24 23 25 19 8 9 10 11 12 13 14 15 18 21 22 20 17 16 7 4 14 1 2 3 6 5 23...

Page 25: ...26 Igniter 21803 27 Ring Bowed 08460 28 Ring Flat 05847 29 Orifice with Rings 21802 30 Chamber Heat with Igniter Orifice and Burner Plate 21799 31 Guard Inlet 21792 32 Case Top 21793 33 Handle with Sc...

Page 26: ...the d date o of p purchase by t the e end u user Warranty is automatic if a component is found defective within 12 months of the date code marked on the part If the defect occurs more than 12 months l...

Reviews: