12

B. Single Stage Thermostat

1. 

Operate on first stage heat only.

2.

Operate on second stage heat only.

C Building Controller Connections - Heating 

(Non-Power Contacts)

1. Operate on first stage heat only.

2. Operate on second stage heat only.

IND
L1
HSI
HSIG
L2
W
PSI
FSI
GV
PSO
FSG
C

YELLOW

BLUE

RED

BROWN

BLACK

GREEN

YELLOW

BLACK

WHITE

SINGLE STAGE
THERMOSTAT

RED

HI

LO

C

GAS CONTROL VALVE

IGNITION CONTROL

HIGH LIMIT SWITCH

BROWN

GREEN

GROUND

TRANSFORMER

WHITE

BROWN

YELLOW

GROUND

GREEN

GROUND

TRANSFORMER

IND
L1
HSI
HSIG
L2
W
PSI
FSI
GV
PSO
FSG
C

GREEN

BROWN

BROWN

YELLOW

YELLOW

GAS CONTROL VALVE

GROUND

RED

BLACK

WHITE

GREEN

HI

LO

C

BUILDING CONTROLLER 
(HEAT CONTACT)

TO CONTROL

FROM CONTROL

LEAVE WIRE
NUT ON LEAD

HIGH LIMIT SWITCH

GAS CONTROL VALVE

TRANSFORMER

GREEN

GROUND

BLACK

WHITE

YELLOW

BUILDING CONTROLLER 
(HEAT CONTACT)

TO CONTROL

FROM CONTROL

IND
L1
HSI
HSIG
L2
W
PSI
FSI
GV
PSO
FSG
C

BROWN

YELLOW

BROWN

LO

HI

IGNITION CONTROL

IGNITION CONTROL

C

HIGH LIMIT SWITCH

24V

120V

24V

120V

24V

120V

RED

RED

GROUND

IND
L1
HSI
HSIG
L2
W
PSI
FSI
GV
PSO
FSG
C

TRANSFORMER

BLACK

WHITE

YELLOW

GREEN

GROUND

GREEN

GROUND

HIGH LIMIT SWITCH

YELLOW

BLUE

RED

BLACK

LO

YELLOW

BROWN

BROWN

GREEN

GROUND

C

HI

RED

LEAVE WIRE
NUT ON LEAD

IGNITION CONTROL

24V

120V

GAS CONTROL VALVE

SINGLE STAGE
THERMOSTAT

Summary of Contents for Therma Grow HW220

Page 1: ...row Greenhouse Heaters View this manual online at www lbwhite com ATTENTION ALL USERS This heater has been tested and evaluated by C S A International in accordance with Canadian Gas Association Stand...

Page 2: ......

Page 3: ...ents paint thinner dust particles or unknown chemicals Failure to follow these instructions may result in a fire or explosion Fire or explosions can lead to property damage personal injury or loss of...

Page 4: ...y questions about the use of the equipment or its application The L B White Co Inc has a policy of continuous product improvement It reserves the right to change specifications and design without noti...

Page 5: ...cally operated and electrically interlocked with the heater to prevent heater operation if air inlet and exhaust outlet do not open when heating is required Model Indoor Mounting Air Exchange Requirem...

Page 6: ...fore you return Properly trained service people must repair the leak check for further leakages and then relight the appliance for you WARNING Do not use this heater for heating human living quarters...

Page 7: ...te this heater with any safety device that has been bypassed Do not operate this heater unless all of these features are fully functioning 6 Do not operate the heater with its door open or panel remov...

Page 8: ...range specified on the dataplate at all times Contact your gas supplier or the L B White Co Inc if you have any questions 5 The heater s gas regulator with pressure relief valve should be installed ou...

Page 9: ...ure you know how to shut off the gas supply to the building and also to the individual heater Contact your fuel gas supplier if you have any questions 17 Any defects found in performing any of the ser...

Page 10: ...rovided in the duct kit Ensure the motorized air inlet and the heater s air inlet are kept free of any blockages FIG 4a Blower Outlet View FIG 4c Side View FIG 4d Alternate Air Inlet Locations ENG BYN...

Page 11: ...IG 6 2 Assemble eyebolts and chain according to the illustration and tighten all eyebolts securely FIG 7 3 Ensure the heater is securely fastened to overhead supports and is hanging level Check crossw...

Page 12: ...ent position the heater fan operates continuously In the vent mode the heater then supplements or provides air circulation within the greenhouse This heat vent capability can be controlled by a buildi...

Page 13: ...GREEN BROWN BROWN YELLOW YELLOW GAS CONTROL VALVE GROUND RED BLACK WHITE GREEN HI LO C BUILDING CONTROLLER HEAT CONTACT TO CONTROL FROM CONTROL LEAVE WIRE NUT ON LEAD HIGH LIMIT SWITCH GAS CONTROL VAL...

Page 14: ...s view is to show general assembly of the components only The regulator must always be mounted so its vent regardless of location on the regulator is always pointed downward 3 Tighten all connections...

Page 15: ...art again and shortly thereafter ignition will occur NOTE It is normal for air to be trapped in the gas hose on new installations The heater may attempt more than one trial for ignition before the air...

Page 16: ...ther flammable vapors and liquids 2 Have your gas supplier check all gas piping annually for leaks or restrictions in gas lines 3 Regulators must be periodically inspected to make sure the regulator v...

Page 17: ...air or a soft dry rag Do not use files drills broaches etc to clean the orifice Doing so may enlarge the hole causing combustion or ignition problems Replace the orifice if it cannot be cleaned proper...

Page 18: ...icates the contacts of the switch have opened 4 Allow the switch cool down for about a minute before firmly pressing the red reset button on the switch 5 Check for electrical continuity across the swi...

Page 19: ...e inlet pressure is correct but the burner manifold pressure does not agree with that specified on the dataplate then the HI and LO heat output feature of the gas control valve requires adjustment 5 T...

Page 20: ...d shield 3 Ensure the igniter is located so the its lip on back side of igniter is resting on the edge of the mounting bracket and the mounting hole in the igniter aligns with the mounting hole in the...

Page 21: ...ermostat Thermostat closes and returns 24 volts to terminal W on ignition control Red light on ignition control is illuminated Ignition control sends flame sense current to flame sensor Ignition contr...

Page 22: ...ed to power supply Check breakers Is proper voltage delivered to selector switch Check all wiring for defects Repair or repalce if needed Yes Does selector switch send voltage to the transformer Check...

Page 23: ...f ignition is not achieved after the third trial the heater will lock out and the ignition control module will present the three time flash pattern Either recycle the heater or wait for heater to atte...

Page 24: ...sary No Is fan wheel plugged with dirt Is there an obstruction in blower outlet preventing air proving switch closure No Are 115 volts sent from ignition control terminal IND to motor relay No If impr...

Page 25: ...e and component Repair or replace as necessary or replace ignition control Provide proper pressure to heater and check with a gauge Check for voltage to switch Check wiring and repair if defective If...

Page 26: ...mbly and housing Repair or replace as necessary Yes Reconnect wires to capacitor Defective capacitor Replace the motor No Yes Are wires disconnected from capacitor No Five Times Rapid On Off cycling o...

Page 27: ...26 Electrical Connection and Ladder Diagram 115 Volt Supply...

Page 28: ...27 230 Volt Supply TRANSFORMER 24 VOLT 120 VOLT...

Page 29: ...box within the appliance that provides an area where burner flame mixes with combustion air thereby providing heat High Limit Switch Safety device wired into the control system which is used to break...

Page 30: ...Parts Identification PARTS SCHEMATIC 29 39 40 41 26 38 25 21 29 27 31 37 36 35 34 33 14 13 15 18 20 19 16 17 6 7 8 9 10 11 12 4 3 2 1 5 28 24 23 22 32 30...

Page 31: ...9 19 Flame Sensor 520139 20 High Limit Switch LP Gas 572501 Natural Gas 505566 21 Heat Chamber LP Gas 572499 Natural Gas 572500 22 Boot Selector Switch 571939 23 Selector Switch w Boot 571906 24 Contr...

Page 32: ...of the equipment and in any event L B White s liability in connection with the equipment including for claims based on negligence or strict liability is limited to the purchase price Some states do no...

Reviews: