Oval 80
v.2
and Sentinel
v.2
Radiant Tube Heaters
www.lbwhite.com
Owner’s Manual • Oval 80
v.2
and Sentinel
v.2
12
1. Plan the installation. Determine location for the heater
to optimize its heat pattern, keeping in mind cooler
regions in the house (end walls, and curtains) and
clearances to combustibles.
2. Hang the burner box. See Fig. 5. Maintain clearances
to combustibles as shown in Fig. 1.
3. From the burner box chain, measure the distances
shown in Fig. 6 or 7 depending on if a Sentinel or
Oval 80 heater is being installed.
Aligning to the
center of the burner box discharge
, hang
chains at these points, using open eye hooks.
Refer to Fig. 8 (on next page) and the following instructions:
1. Slide a tube clamp over the non-swaged end of the 10 ft.
bright aluminized tube. One aluminized tube per tube kit.
2. Install the tube over the swaged discharge tube on the
burner box:
a. Tube weld seam must be down.
b. Non-swaged end of tube must be complete-
ly pushed over swaged end of adjoining
tube.
c. Clamp must be centered over tube
connection.
d. Clamp bolts must be up.
e. Clamp bolts must be tight.
-- Tighten both bolts fi rmly.
-- Tighten both bolts to 35 ft.-lbs.
-- Finish tightening bolts:
-- Sentinel Heaters: Finish tightening bolts
to 65 ft. lbs.
-- Oval 80 Heaters: Finish tightening bolts
to 44-59 ft. lbs.
Initial Setup
FIG. 5
FIG. 6 SENTINEL
FIG. 7 OVAL 80
JOIST
OPEN EYE HOOKS
IN LINE WITH
EYE BOLTS ON
BURNER BOX
OPEN EYE BOLT
.30m
BURNER
DISCHARGE
TIGHTEN HOOKS
SECURELY
Hanging the Tubes
A
B
C
D
E
HEATER
LENGTH
TRUSS
CENTERS
A - B B - C C - D D - E
4 FOOT
50 FOOT
4
4
12
8
5 FOOT
50 FOOT
5
5
10
10
10 FOOT
50 FOOT
5
5
10
10
*
* A SUPPORT MUST BE CREATED BETWEEN THE TRUSS
BURNER BOX
HANGING CHA
HANGING CHAIN DISTANCES
(FT)
(FT)
(FT)
(FT)
HANGING CHAINS
BURNER BOX
20 FOOT
20 FOOT
20 FOOT
4
4
4
8
5
5
5
5
5
5
5*
5*
F
A
B
C
D
E
F
G
HEATER
LENGTH
TRUSS
CENTERS
A - B B - C C - D D - E E - F F - G
4 FOOT
30 FOOT
40 FOOT
50 FOOT
4
4
4
4
4
4
12
12
12
8
8
8
12
12
8
5 FOOT
30 FOOT
40 FOOT
50 FOOT
5
5
5
5
5
5
10
10
10
10
10
10
5
10
5
10 FOOT
30 FOOT
40 FOOT
50 FOOT
5
5
5
5
5
5
10
10
10
10
10
10
5
10
5
*
*
*
*
*
* A SUPPORT MUST BE CREATED BETWEEN THE TRUSSES
BURNER BOX
HANGING CHAINS
HANGING CHAIN DISTANCES
(FT)
(FT)
(FT)
(FT)
(FT)
(FT)
1Ft.
18. Do not exceed input rating stamped on the
dataplate of the heater. Do not exceed the burner
manifold pressure stated on the dataplate. Do
not use an ori
fi
ce size different than speci
fi
ed for
the speci
fi
c input rating of this heater, fuel type
con
fi
guration and altitude.