background image

LP ggas aand nnatural ggas hhave m

man-m

made oodorants aadded sspecifically ffor ddetection oof ffuel ggas lleaks.

If aa ggas lleak ooccurs, yyou sshould bbe aable tto ssmell tthe ffuel ggas.  

THAT’S  YYOUR  S

SIGNAL  TTO  G

GO  IINTO  IIMMEDIATE  AACTION!

Do not take any action that could ignite the fuel gas.  Do

not operate any electrical switches.  Do not pull any

power supply or extension cords.  Do not light matches

or any other source of flame.  Do not use your

telephone.

Get everyone out of the building and away from the area

immediately.

Close all propane (LP) gas tank or cylinder fuel supply

valves, or the main fuel supply valve located at the

meter if you use natural gas.

Propane (LP) gas is heavier than air and may settle in

low areas.  When you have reason to suspect a propane

leak, keep out of all low areas.  

Natural gas is lighter than air and can collect around

rafters or ceilings.

Use your neighbor’s phone and call your fuel gas 

supplier and your fire department.  Do not re-enter the

building or area.

Stay out of the building and away from the area until

declared safe by the firefighters and your fuel gas 

supplier.

FINALLY,  let the fuel gas service person and the

firefighters check for escaped gas.  Have them air out

the building and area before you return.  Properly

trained service people must repair the leak, check for

further leakages, and then relight the heater for you.

WARNING

Do not use this radiant heater for heating human living

quarters.

Do not use in unventilated areas.

The flow of combustion and ventilation air must not be

obstructed.

Proper ventilation air must be provided to support the

combustion air requirements of the heater being used.

Refer to the specification section of the Owner’s

Manual, heater’s dataplate, or contact the 

L.B. White Company to determine combustion air

ventilation requirements of the heater.

Lack of proper ventilation air will lead to improper

combustion.

Improper combustion can lead to carbon monoxide

poisoning in humans leading to serious injury or death.

Symptoms of carbon monoxide poisoning can include

headaches, dizziness and difficulty in breathing.

Symptoms of improper combustion affecting livestock

can be disease, lower feed conversion, or death.

Asphyxiation Hazard

Some  ppeople  ccannot  ssmell  w

well.    S

Some  ppeople  ccannot

smell  tthe  oodor  oof  tthe  m

man-m

made  cchemical  aadded  tto

propane ((LP) oor nnatural ggas.  YYou m

must ddetermine iif yyou

can ssmell tthe oodorant iin tthese ffuel ggases.  

Learn to recognize the odor of propane (LP) gas and

natural gas.  Local propane (LP) gas dealers and your

local natural gas supplier (utility) will be more than

happy to give you a “scratch and sniff” pamphlet.  Use it

to become familiar with the fuel gas odor.  

Smoking can decrease your ability to smell.  Being

around an odor for a period of time can affect your

sensitivity to that particular odor.  Odors present in

animal confinement buildings can mask fuel gas odor.

The  oodorant  iin  ppropane  ((LP)  ggas  aand  nnatural  ggas  iis

colorless  aand  tthe  iintensity  oof  iits  oodor  ccan  ffade  uunder

some ccircumstances.

If there is an underground leak, the movement of gas

through the soil can filter the odorant.  

Propane (LP) gas odor may differ in intensity at different

levels.  Since propane (LP) gas is heavier than air, there

may be more odor at lower levels.

Always  bbe  ssensitive  tto  tthe  sslightest  ggas  oodor. If you

continue to detect any gas odor, no matter how small,

treat it as a serious leak.  Immediately go into action as

discussed previously.

Safety Precautions

FUEL GAS ODOR

ODOR FADING -- NO ODOR DETECTED

ATTENTION -- CRITICAL POINTS TO REMEMBER!

Propane (LP) gas and natural gas have a distinctive

odor.  Learn to recognize these odors.  (Reference “Fuel

Gas Odor” and “Odor Fading” sections above.

If you have not been properly trained in repair and service

of propane (LP) gas and natural gas fueled heaters, then

do not attempt to light the heater, perform service or

repairs, or make any adjustments to the heater on a

propane (LP) gas or natural gas fuel system.

Even if you are not properly trained in the service and

repair of radiant heaters, ALWAYS be consciously aware

of the odors of propane (LP) gas and natural gas.

A periodic “sniff test” around the heater or at the

heater’s joints; i.e. hose, connections, etc., is a good

safety practice under any conditions.  If you smell even

a small amount of gas, CONTACT YOUR FUEL GAS

SUPPLIER IMMEDIATELY.  DO NOT WAIT!

5

Summary of Contents for I17

Page 1: ...may have call us toll free at 1 800 345 7200 Owner s Manual and Instructions Spark Ignition Infraconic Agricultural Building Radiant Heaters ATTENTION ALL USERS This heater has been tested and evalua...

Page 2: ......

Page 3: ...injury or loss of life GENERAL HAZARD WARNING Failure to comply with the precautions and instructions provided with this brooder can result in Death Serious bodily injury or burns Property damage or...

Page 4: ...te distributor or the L B White Co Inc for assistance or if you have any questions about the use of the heater or its application The L B White Co Inc has a policy of continuous product improvement It...

Page 5: ...applicable 1 There are other factors that will affect the quantity of animals each heater can cover These include building ventilation and control systems building insulation building size and populat...

Page 6: ...hing Symptoms of improper combustion affecting livestock can be disease lower feed conversion or death Asphyxiation Hazard Some p people c cannot s smell w well S Some p people c cannot smell t the o...

Page 7: ...uired have a qualified gas heater service agency replace the complete part Do not attempt to repair 5 This heater is intended for the heating of livestock in agricultural animal confinement buildings...

Page 8: ...ttings and adapters upstream of the gas control with approved gas leak detectors In the event a gas leak is detected check the components involved for cleanliness and proper application of pipe compou...

Page 9: ...s designed for either L P vapor withdrawal or natural gas depending on model number Do not use this heater in an LPG liquid withdrawal system Do not permit LPG in liquid form to enter the heater at an...

Page 10: ...the elastic on the filter and slide the filter over the sleeve Make sure the elastic of the filter is covering the top of the sleeve and that the seam of the filter is perpendicular to the canopy edge...

Page 11: ...fully clogged with dust and dirt A dust choked filter will restrict the combustion air causing improper combustion Signs of improper combustion include backflashing of flame into the venturi tube yel...

Page 12: ...ill occur 5 Set the building s temperature control to desired temperature This heater includes a spark ignition control module for purposes of controlling the timing of the ignition process of the hea...

Page 13: ...ou can no longer feel heat coming from the heater canopy or combustion cones 2 Using a soft bristle brush brush off all exterior surfaces of the heater Pay particular attention to the air inlet hole o...

Page 14: ...ny debris that may have accumulated 2 The a appliance a area s shall b be k kept c clear a and f free f from combustible m materials g gasoline a and o other flammable v vapors a and l liquids 3 Regul...

Page 15: ...rom the orifice body by turning counter clockwise 6 Use compressed air to clean the orifice hole Do not push or poke any small file broach etc through orifice holes Doing so may enlarge the hole causi...

Page 16: ...sconnect the high voltage ignition lead 10 Remove the connector nut from the ignition cable This same nut will be slid over the replacement ignition cable and used to create a water tight connection a...

Page 17: ...ater top 6 Remove the igniter from the heater The igniter rod and its insulating ceramic body must be rigid within its mounting bracket If the igniter rod or its body are capable of movement the ignit...

Page 18: ...e heater with a bypassed high limit switch may lead to overheating possibly resulting in a fire with subsequent damage to the heater building damage or loss of livestock TERMINAL MOUNTING LEG RESET BU...

Page 19: ...as control valve Tighten securely See Fig 15 2 Connect the gas supply hose to the hose fitting on the test kit Tighten securely See Fig 15 3 Reconnect the heater to its electrical supply 4 Open the ma...

Page 20: ...oblem is identified by the flow chart OPERATION SEQUENCE A call for heat occurs from building thermostat Line voltage is sent from building s temperature control to heater s ON OFF switch Switch sends...

Page 21: ...High Limit Switch and Determine Cause of Tripping No No Is ON OFF Switch on Heater Positioned to ON Position the Switch to ON Yes No Is Proper Voltage Supplied to Heater Power Cord Provide Proper Vol...

Page 22: ...ed Methods in this Owner s Manual No No I s Heater s Venturi Tube Reasonably Clean Clean Heater According to Prescribed Cleaning Methods in this Owner s Manual Yes No Is Flame Sense Ground Lead Proper...

Page 23: ...in this Owner s Manual Yes No Is Dust Filter Clean Are Inner Cone Inlet Venturi Injector Body or Burner Orifice Plugged Clean all Components According to Cleaning Instructions in Owner s Manual If Com...

Page 24: ...LACK GREEN WHITE SPARK IGNITION CONTROL NOTE POWER CORD IS CONNECTEDTO THERMOSTAT OR BUILDING ENVIRONMENTAL CONTROL SYSTEM ELECTRICAL CONNECTION DIAGRAM N1 N2 GND L1 MV ON OFF SWITCH POWER CORD GAS CO...

Page 25: ...ignition control systems Ignites gas by spark Ignition Control Module Electronic device which controls the ignition sequence and operation of the heater Injector Body Allows combustion air to be drawn...

Page 26: ...Parts Identification PARTS SCHEMATIC 11 4 5 10 34 6 17 8 26 32 25 37 27 28 22 35 24 23 31 30 7 31B 1 31A 29 3 9 2 12 36 20 16 21 13 41 1 14 19 18 33 39 42 40 38 25...

Page 27: ...n 25 Orifice Burner L P Gas 310 21562 310 20573 Natural Gas 310 09776 310 21000 26 Injector Body w Air Register Plate L P Gas 500 21838 500 20672 Natural Gas 500 21837 500 21559 27 Retaining Screw for...

Page 28: ...te o of p purchase by t the e end u user Warranty is automatic if a component is found defective within 12 months of the date code marked on the part If the defect occurs more than 12 months later tha...