background image

26

Heater Component Function

Air Proving Switch

Safety device used to insure that the proper air flow is being

achieved before the gas valve is opened.

Burner

Cast iron component used to channel gas and provide an

area at which the fuel may ignite.

Burner Orifice

Brass metering device used to feed gas to burner at a

specific rate.

Direct Spark Ignition Control Module

Electronic printed circuit board which sends and receives

voltages to various controls in an automatic ignition system.

An important safety feature of the control board is that it will

shut down the entire heater, thereby stopping the flow of

fuel gas if burner flame goes out.

Fan Housing

Chamber used for delivering air for efficient air movement.

Fan Wheel

Component used in conjunction with the motor and fan

housing to pull the hot air from heater and blow it into room

for heating (also known as a squirrel cage).

Gas Control Valve

Electrical device consisting of a low pressure regulator and

electrical solenoids used for the control of gas flow to the

burner assembly.  A feature of the control valve is it’s ability

to modulate from a first stage (minimum) heat position to a

second stage (maximum) heat position, if needed, to satisfy

the temperature requirements of the greenhouse.  This

results in less temperature variation and potentially lower

fuel consumption.

Gas Hose

Flexible connector used to convey gas from supply line in

building to heater.

Heat Chamber

Metal fire box within the heater that provides an area where

burner flame mixes with combustion air, thereby providing

heat.

High Limit Switch

Safety device wired into the control system which is used to

break an electrical circuit to the gas control valve in event of

overheat situation.

Igniter

Ignition device used on automatic direct spark ignition

control systems.  Ignites gas by spark.

Motor

Electric device used to force preheated air through the

heater and to circulate heat within a certain area.  Converts

electrical energy into mechanical energy.

Regulator

Mechanical device used in L.P. and natural gas distribution

systems to reduce a higher inlet pressure to a preset lower

pressure.  The regulator is responsible to supply a steady

outlet pressure to the heater(s) despite changes in inlet

pressure, heater demand and weather conditions.

Selector Switch

Electrical device which is used to allow the end user to use

the heater in either a heating or ventilation application.

Thermostat 

(Optional Accessory)

A two stage electrical device which responds to more closely

match a heat to demand requirement.  The thermostat

incorporates two independent control circuits which

interconnect to the heater’s two stage gas control valve,

thereby providing low or high heat depending on thermostat

setpoint.  

Transformer

Electrical control used to accept line power supply primary

voltage and reduce it to lower secondary voltage to operate

certain control systems.

Summary of Contents for FUEL HD120

Page 1: ...idence in our products and welcome any suggestions or comments you may have call us toll free at 1 800 345 7200 Owner s Manual and Instructions GreenGro Plus Greenhouse Heaters ATTENTION ALL USERS Thi...

Page 2: ......

Page 3: ...nal injury or loss of life GENERAL HAZARD WARNING Failure to comply with the precautions and instructions provided with this heater can result in Death Serious bodily injury or burns Property damage o...

Page 4: ...nce or if you have any questions about the use of the equipment or its application The L B White Co Inc has a policy of continuous product improvement It reserves the right to change specifications an...

Page 5: ...et and exhaust outlet do not open when heating is required HD120 Propane Natural Gas Gas M Mo od de el l Indoor Mounting Air Exchange Requirements 1 Burner Manifold Pressure In W C Net Weight lbs Ship...

Page 6: ...ans leading to serious injury or death Symptoms of carbon monoxide poisoning can include headaches dizziness and difficulty in breathing Asphyxiation H Hazard Some p people c cannot s smell w well S S...

Page 7: ...high limit switch and an air proving switch Never operate this heater with any safety device that has been bypassed Do not operate this heater unless all of these features are fully functioning 6 Do n...

Page 8: ...mber 23578 4 The heater must have the proper gas regulator installed for the application A regulator must be connected to the gas supply so that gas pressure at the inlet to the gas valve is regulated...

Page 9: ...Manual Make sure you know how to shut off the gas supply to the building and also to the individual heater Contact your fuel gas supplier if you have any questions 17 Any defects found in performing...

Page 10: ...chain hanging kit part number 08748 Refer to the following instructions and illustrations 1 Assemble eyebolts and chain according to the illustration and tighten all eyebolts securely See Fig 2 FIG 2...

Page 11: ...THERMOSTAT GROUND BROWN RED RED YELLOW YELLOW WHITE BLACK WHITE BLACK GREEN 8 9 10 HI LO YELLOW BLUE RED NIPPLE HOSE ADAPTER TEE NIPPLE CAP TO GAS CONTROL...

Page 12: ...ctrical connection jumper between relays in building control to allow staging transition of gas control valve D Heat V Vent B Building C Control C Connections Using N Non P Powered C Contacts Remove j...

Page 13: ...er at terminals 1 and 2 Remove black leads at terminals 3 and 4 to selector switch Remove white leads at terminal 6 to selector switch Add neutral s of control contacts at terminal 5 HEAT MODE Add con...

Page 14: ...4 The direct spark ignition DSI control board within this heater is self diagnostic The board works in conjunction with a light emitting diode L E D built into the selector switch The L E D will flash...

Page 15: ...Periodic cleaning and inspection as well as proper maintenance are essential to avoid serious injury or property damage 1 The area surrounding the heater shall be kept clear and free from combustible...

Page 16: ...on FIG 9 AIR PROVING SWITCH Service Instructions 1 Close the fuel supply valve to the heater and disconnect the heater s electrical supply before servicing unless it is necessary to have the valve ope...

Page 17: ...R AND FLAME SENSOR BLOWER OUTLET OF HEATER AIR PROVING SWITCH ARM OF FLAPPER AIR PROVING SWITCH ARM FANWHEEL PIVOT POINT OF FLAPPER EDGE OF FLAPPER PIVOT POINT OF FLAPPER FLAPPER 31 7 MMTO 34 9 MM 1 E...

Page 18: ...om the switch which indicates the contacts of the switch have opened Check for lack of electrical continuity across the switch terminals to verify contacts have opened 5 Allow the switch cool down for...

Page 19: ...let pressure gauges agree with that specified on the dataplate If so then no further checking or adjustment is required Proceed to section D 3 If the inlet pressures do not agree with that specified o...

Page 20: ...s Page A Motor Does Not Run 24 B Motor Hums Does Not Run 24 Components should be replaced only after each step has been completed and replacement is suggested in the flow chart Refer to the Servicing...

Page 21: ...Are 24 Volts Supplied from Transformer No No No No No Yes Is Proper Voltage Supplied to Transformer No Yes Yes No See One Time Flash L E D Light is Defective Replace Ignition Control Check Dataplate...

Page 22: ...ns Yes Repair Air Proving Switch One T T ime Flash P P attern Begins Immediately After C C ondition Occurs Is Air Proving Switch Stuck Closed Check Continuity Is Airflow Switch Binding Repair Yes Yes...

Page 23: ...Proving Switch No Is Fan Loose On Motor Shaft Yes Tighten Fan Blade Set Screw Is Proper Voltage Supplied to Fan Motor No Yes Defective Motor or Capacitor Replace Motor or Capacitor Is Ignition Module...

Page 24: ...curs T T he Module H H as Gone i i nto S S afety Lockout Is Proper Fuel Supplied to Heater Inlet Connect Proper Fuel Supply to Heater Open All Gas Shutoff Valves Yes No Is Proper Gas Pressure Supplied...

Page 25: ...onnections Verify Proper Voltage with a Voltage Tester Contact a Qualified electrician if Proper voltage is not Present No No Yes Is Proper Voltage Supplied to Selector Switch from Power Cord No VENTI...

Page 26: ...TER MALFUNCTION CHECK FOR PROPER OPERATION AFTER SERVICING WARNING THIS HEATER MAY START AT ANY TIME FAN MOTOR TRANSFORMER AIR PROVING SWITCH BLUE BLUE HIGH VOLTAGE IGNITION LEAD IGNITER FLAME SENSOR...

Page 27: ...lexible connector used to convey gas from supply line in building to heater Heat Chamber Metal fire box within the heater that provides an area where burner flame mixes with combustion air thereby pro...

Page 28: ......

Page 29: ...Switch High Limit 05566 18 Chamber Heat 23566 19 Case Assembly with Doors and Latches 2 20465 20 Latch Assembly 20959 21 Harness Wiring 23534 22 Control Ignition 22461 23 Transformer 120 24 v 81218 2...

Page 30: ...date o of p purchase by t the e end u user Warranty is automatic if a component is found defective within 12 months of the date code marked on the part If the defect occurs more than 12 months later t...

Reviews: