Foreman Ductable Oil Indirect-Fired Heater

Owner’s Manual • Foreman

 

Start-Up Instructions

For initial start-up after heater installation, follow steps 

1-5. For normal start-up, set the thermostat above room 

temperature or set thermostat selector switch to the 

manual position.

1. Follow all ventilation and safety information.

2. Fill tank with fuel.

3.  This heater is wired with a ground connection for 

your protection against electrical shock hazard. The 

heater must be connected directly to a properly wired 

and grounded electrical supply. Minimum breaker 

size: CI230-15 amp, CI500/CI750-20 amp.

4.  Set thermostat to desired room temperature or set 

thermostat selector switch to the manual position.

5.  This heater has a rocker style selector switch

located on the side of the heater. This switch

allows for either heat mode or ventilate mode 

(no heat).

6.  When the switch is set to heat          , three status 

lights will be activated in sequence as specific circuits 

are checked by the heater controller. If the heater 

does not light, and a status light is off, refer to the 

trouble shooting section of this manual.

7.  Do not exceed input rating stamped on nameplate 

or manufacturer’s recommended pump pressure for 

nozzle used. Make certain that the primary air supply 

to main burner is open and free of dust, dirt and 

debris for complete, proper combustion.

Summary of Contents for Foreman

Page 1: ...vneR to view maintenance videos for L B White heaters WORLD PROVIDER INNOVATIVE HEATING SOLUTIONS 411 Mason Street Onalaska WI 54650 800 345 7200 608 783 5691 608 783 6115 fax www lbwhite com Foreman Ductable Indirect Fired Oil Heater CI230 230 000 Btuh 67 4 kW 1 2 Fuel Oil Owner s Manual and Instructions View this manual online at www lbwhite com Requires an app like QR Droid for Android or for i...

Page 2: ... amp CI500 CI750 20 amp 4 Set thermostat to desired room temperature or set thermostat selector switch to the manual position 5 This heater has a rocker style selector switch located on the side of the heater This switch allows for either heat mode or ventilate mode no heat 6 When the switch is set to heat three status lights will be activated in sequence as specific circuits are checked by the he...

Page 3: ... Out This heater is equipped with the Beckett GeniSys Advanced Burner Control The GeniSys is used with a suitable cad cell flame sensor to control the oil burner motor igniter and oil solenoid valve The GeniSys Burner controller has one ignition trial If ignition is not achieved the GeniSys burner control will enter a soft lock out mode Soft lockout the control has shut down for one of the followi...

Page 4: ...move the fan wheel assembly and brush or blow off and dust that may have accumulated on the fin Additionally make sure the burner air inlet is free of dust accumulation Clean all components of the heater with pressurized air a dry brush or a dry cloth Maintenance Instructions BEFORE EACH USE Check the area surrounding the heater to ensure it is clear and free of combustible materials gasoline and ...

Reviews: