Attention

This heater has been tested 
and evaluated by OMNI Test 
Laboratories  in accordance 
with the requirements of CSA 
B140.8-1967(R2015) and  
UL 733-2019 and is listed and 
approved as a ductable indirect 

oil-fired forced-air construc

-

tion heater with application 
for the temporary heating of 
buildings under construction, 
alteration, or repair. CHECK 
WITH YOUR LOCAL FIRE 
SAFETY AUTHORITY, YOUR 
FUEL GAS SUPPLIER, OR 
THE L.B. WHITE COMPANY 
IF YOU HAVE QUESTIONS  
REGARDING APPLICATIONS 
OR INSTALLATION.

www.lbwhite.com

SCAN THIS

with your smartphone or

visit http://goo.gl/nvneR 

to view maintenance

videos for L.B.White heaters.*

WORLD PROVIDER - INNOVATIVE HEATING SOLUTIONS

411 Mason Street, Onalaska, WI 54650  •  800-345-7200  •  608-783-5691  •  608-783-6115 (fax)  •  www.lbwhite.com

Foreman

Ductable Indirect-

Fired Oil Heater

CI230 

230,000 Btuh / 67.4 kW

  

#1 / #2 Fuel Oil

Owner’s Manual and Instructions

View this manual online at www.lbwhite.com

*  Requires an app like QR Droid

for Android or for iPhone

.

Report No: 0545HH002S

The herein installation instructions are the L.B. White Co. LLC 

suggested recommendations and guidelines for temporary or 

permanent installation of the L.B. White Co. LLC heaters. Local, 

state, and electrical and safety code requirements supersede these 

guidelines.

This is not a full Manual.  Please visit www.lbwhite.com for complete manual

NOTICE

Summary of Contents for Foreman

Page 1: ...vneR to view maintenance videos for L B White heaters WORLD PROVIDER INNOVATIVE HEATING SOLUTIONS 411 Mason Street Onalaska WI 54650 800 345 7200 608 783 5691 608 783 6115 fax www lbwhite com Foreman Ductable Indirect Fired Oil Heater CI230 230 000 Btuh 67 4 kW 1 2 Fuel Oil Owner s Manual and Instructions View this manual online at www lbwhite com Requires an app like QR Droid for Android or for i...

Page 2: ... amp CI500 CI750 20 amp 4 Set thermostat to desired room temperature or set thermostat selector switch to the manual position 5 This heater has a rocker style selector switch located on the side of the heater This switch allows for either heat mode or ventilate mode no heat 6 When the switch is set to heat three status lights will be activated in sequence as specific circuits are checked by the he...

Page 3: ... Out This heater is equipped with the Beckett GeniSys Advanced Burner Control The GeniSys is used with a suitable cad cell flame sensor to control the oil burner motor igniter and oil solenoid valve The GeniSys Burner controller has one ignition trial If ignition is not achieved the GeniSys burner control will enter a soft lock out mode Soft lockout the control has shut down for one of the followi...

Page 4: ...move the fan wheel assembly and brush or blow off and dust that may have accumulated on the fin Additionally make sure the burner air inlet is free of dust accumulation Clean all components of the heater with pressurized air a dry brush or a dry cloth Maintenance Instructions BEFORE EACH USE Check the area surrounding the heater to ensure it is clear and free of combustible materials gasoline and ...

Reviews: