background image

AIR DIVERTER 

INSTALLATION INSTRUCTIONS

10. Light according to instructions on heater or within

owner's manual.

11. It is extremely important to use the proper size and

type of gas supply line to assure proper functioning of

the heater.  Contact your fuel gas supplier for proper

line sizing and installation.

12. Make sure the heater has the proper gas regulator for

the application.  A regulator must be connected to the

gas supply so that gas pressure at the inlet to the gas

valve is regulated within the range specified on the

dataplate at all times.  Contact your gas supplier, or

the L.B. White Co., Inc. if you have any questions.

13. This heater can be configured for use with either L.P.

gas vapor withdrawal or natural gas.  Consult the

dataplate, located on interior of the burner end or

motor end door, for the gas configuration of the

specific heater.  Do not use the heater in an L.P. gas

liquid withdrawal system or application.  If you are in

doubt, contact the L.B. White Co., Inc.

14. Eventually, like all electrical/mechanical devices, the

thermostat can fail.  Thermostat failure may result in

either an underheating or overheating condition which

may damage critical products and/or cause animal

injury or death.  Critical products and/or animals

should be protected by a separate back-up control

system that limits high and low temperatures and also

activates appropriate alarms.

15. Take time to understand how to operate and maintain

the heater by using this Owner’s Manual.  Make sure

you know how to shut off the gas supply to the building

and also to the individual heater.  Contact your fuel

gas supplier if you have any questions.

16. Any defects found in performing any of the service or

maintenance procedures must be eliminated and

defective parts replaced immediately.  The heater

must be retested by properly qualified service

personnel before placing the heater back into use.

Alternate Air Diverter Installations

TABS

DIVERTER 
HALVES

OUTLET
SCREWS

FORMED 
OUTLET GUARD

NOTCHES IN MOUNTING TABS

1. Optional air diverters can be installed in the heater

outlet to provide direction to the heated air as it exits

the heater.  Installation options include installing the

diverters in such a way as to broadly distribute the air

in two 45 degree paths or to focus the air flow in one

45 degree direction.  See Fig. 1.

.

2. The air diverter’s tabs on each half will “pop” into the

blower outlet between the inside of the case assembly

and the blower housing outlet.  If the notched tabs do

not “pop” into the blower outlet, loosen (do not

remove) the blower outlet screws.  Doing this provides

a gap into which you can insert the tabs.  Retighten

the screws after installation.  

FIG. 1 

(Typical installation allowing two directions of air movement.)

8

Summary of Contents for 346

Page 1: ...or comments you may have call us toll free at 1 800 345 7200 Owner s Manual and Instructions Agricultural Animal Confinement Building Heaters Certification by ATTENTION ALL USERS This heater has been...

Page 2: ......

Page 3: ...ents paint thinner dust particles or unknown chemicals Failure to follow these instructions may result in a fire or explosion Fire or explosions can lead to property damage personal injury or loss of...

Page 4: ...etailed Installation and Service Guide is available at no charge to qualified personnel by contacting the local L B White distributor dealer or the L B White Company Contact your local L B White distr...

Page 5: ...as Natural Gas M Mo od de el l Ventilation Air Required to Support Combustion Burner Manifold Pressure Net Weight lbs Shipping Weight lbs Electrical Supply Volts Hz Phase Amp Draw Dimensions Inches L...

Page 6: ...rained service people must repair the leak check for further leakages and then relight the appliance for you WARNING Do not use this heater for heating human living quarters Do not use in unventilated...

Page 7: ...completely dry In any event do not operate the heater for at least one hour after external washdown 5 For safety this heater is equipped with a manual reset high limit switch Never operate this heater...

Page 8: ...adapters upstream of the gas control with approved gas leak detectors In the event a gas leak is detected check the components involved for cleanliness and proper application of pipe compound before f...

Page 9: ...y a separate back up control system that limits high and low temperatures and also activates appropriate alarms 15 Take time to understand how to operate and maintain the heater by using this Owner s...

Page 10: ...ure heater is securely fastened and is hanging level Check crosswise and lengthwise 3 See Fig 3 for typical indoor installation In any animal confinement building consideration must be given to making...

Page 11: ...cted WARNING Electrical S Shock H Hazard Disconnect the electrical supply before connecting the thermostat to the heater Failure to follow this warning can result in electrical shock leading to person...

Page 12: ...rt period of time for the gas to purge out any air in the pilot line before the pilot stays lit 5 Reinstall the metal cover back over the valve if applicable 6 Connect the heater s electrical cord to...

Page 13: ...venturi ports and the throat of the casting are free of dust accumulation and the area between the heat chamber top and inside case is also free of dust c When washing with water observe and obey the...

Page 14: ...ITCH MOTOR GROUND THERMOSTAT NEUTRAL GROUND MOTOR HIGH LIMIT SWITCH GAS CONTROL VALVE WHITE WHITE WHITE BLACK BLACK BLACK BLACK BLACK GREEN BLACK BLACK BLACK OR RED BLACK OR RED AIR PROVING SWITCH NOT...

Page 15: ...the dual purpose of igniting the main burner and heating the thermocouple Pilot Safety Control Valve A gas control valve which is held open by electrical power supplied by a pilot generator and which...

Page 16: ...PARTS SCHEMATIC Parts Identification 1 2 5 8 6 3 7 4 4 3 11 10 10A 9 12 15 14 13 17 16 19 18 21 22 23 24 25 26 31 31 29 30 32 27 27B 27A 27C L P GAS SUPPLY N G SUPPLY 32 15...

Page 17: ...Box 120 0 03230 9 Thermostat w with B Bracket 500 0 05568 10 Bracket G Gas C Control V Valve 225 2 22095 10A Cover G Gas C Control V Valve 225 2 22096 11 Bracket T Thermostat 220 0 05493 12 Valve P P...

Page 18: ...e d date o of p purchase b by the e end u user Warranty is automatic if a component is found defective within 12 months of the date code marked on the part If the defect occurs more than 12 months lat...

Reviews: