17

Contact your local L.B. White dealer for replacement parts

and service or call L.B. White Co., Inc. at 1-800-345-7200 for

assistance.  Be sure that you have your heater model number

and configuration number when calling.

L.B. White Co., Inc. warrants that the component parts of its

heater are free from defects in material and workmanship,

when properly installed, operated, and maintained in

accordance with the Installation and Maintenance

Instructions, safety guides and labels contained with each

unit.  If, within 1

12 m

months ffrom tthe ddate oof ppurchase bby tthe

end  uuser, any component is found to be defective, 

L.B. White Co., Inc. will at its option, repair 

or replace the defective part or heater, with a new part or

heater, F.O.B., Onalaska, Wisconsin.  

A warranty card on file at L.B. White will automatically qualify

a unit and its component parts for warranty consideration.  If

a warranty card is not on file, a copy of the bill of sale will be

required to establish warranty qualification.  If neither is

available, the warranty period will be 12 months from date of

shipment from L B. White.  

Warranty Policy

Replacement Parts and Service

EQUIPMENT

PARTS

L.B. White Co., Inc. warrants that replacement parts

purchased from the company and used on the appropriate L.

B. White heater are free from defects both in material and

workmanship for 12  m

months  ffrom  tthe  ddate  oof  ppurchase  bby

the eend uuser.  Warranty is automatic if a component is found

defective within 12 months of the date code marked on the

part.  If the defect occurs more than 12 months later than

the date code but within 12 months from the date of

purchase by the end user, a copy of a bill of sale will be

required to establish warranty qualification. 

The warranty set forth above is the exclusive warranty

provided by L.B. White, and all other warranties, including

any implied warranties or merchantability or fitness for a

particular purpose, are expressly disclaimed.  In the event

any implied warranty is not hereby effectively disclaimed due

to operation of law, such implied warranty is limited in

duration to the duration of the applicable warranty stated

above.  The remedies set forth above are the sole and

exclusive remedies available hereunder.  L.B. White will not

be liable for any incidental or consequential damages

directly or indirectly related to the sale, handling or use of the

heater, and in any event L.B. White's liability in connection

with the heater, including for claims based on negligence or

strict liability, is limited to the purchase price.  

Some states do not allow limitations on how long an implied

warranty lasts, so the above limitation may not apply to you.

Some states do not allow the exclusion or limitation of

incidental or consequential damages, so the above limitation

or exclusion may not apply to you.  This warranty gives you

specific legal rights, and you may also have other rights

which vary from state to state.

Summary of Contents for 346

Page 1: ...or comments you may have call us toll free at 1 800 345 7200 Owner s Manual and Instructions Agricultural Animal Confinement Building Heaters Certification by ATTENTION ALL USERS This heater has been...

Page 2: ......

Page 3: ...ents paint thinner dust particles or unknown chemicals Failure to follow these instructions may result in a fire or explosion Fire or explosions can lead to property damage personal injury or loss of...

Page 4: ...etailed Installation and Service Guide is available at no charge to qualified personnel by contacting the local L B White distributor dealer or the L B White Company Contact your local L B White distr...

Page 5: ...as Natural Gas M Mo od de el l Ventilation Air Required to Support Combustion Burner Manifold Pressure Net Weight lbs Shipping Weight lbs Electrical Supply Volts Hz Phase Amp Draw Dimensions Inches L...

Page 6: ...rained service people must repair the leak check for further leakages and then relight the appliance for you WARNING Do not use this heater for heating human living quarters Do not use in unventilated...

Page 7: ...completely dry In any event do not operate the heater for at least one hour after external washdown 5 For safety this heater is equipped with a manual reset high limit switch Never operate this heater...

Page 8: ...adapters upstream of the gas control with approved gas leak detectors In the event a gas leak is detected check the components involved for cleanliness and proper application of pipe compound before f...

Page 9: ...y a separate back up control system that limits high and low temperatures and also activates appropriate alarms 15 Take time to understand how to operate and maintain the heater by using this Owner s...

Page 10: ...ure heater is securely fastened and is hanging level Check crosswise and lengthwise 3 See Fig 3 for typical indoor installation In any animal confinement building consideration must be given to making...

Page 11: ...cted WARNING Electrical S Shock H Hazard Disconnect the electrical supply before connecting the thermostat to the heater Failure to follow this warning can result in electrical shock leading to person...

Page 12: ...rt period of time for the gas to purge out any air in the pilot line before the pilot stays lit 5 Reinstall the metal cover back over the valve if applicable 6 Connect the heater s electrical cord to...

Page 13: ...venturi ports and the throat of the casting are free of dust accumulation and the area between the heat chamber top and inside case is also free of dust c When washing with water observe and obey the...

Page 14: ...ITCH MOTOR GROUND THERMOSTAT NEUTRAL GROUND MOTOR HIGH LIMIT SWITCH GAS CONTROL VALVE WHITE WHITE WHITE BLACK BLACK BLACK BLACK BLACK GREEN BLACK BLACK BLACK OR RED BLACK OR RED AIR PROVING SWITCH NOT...

Page 15: ...the dual purpose of igniting the main burner and heating the thermocouple Pilot Safety Control Valve A gas control valve which is held open by electrical power supplied by a pilot generator and which...

Page 16: ...PARTS SCHEMATIC Parts Identification 1 2 5 8 6 3 7 4 4 3 11 10 10A 9 12 15 14 13 17 16 19 18 21 22 23 24 25 26 31 31 29 30 32 27 27B 27A 27C L P GAS SUPPLY N G SUPPLY 32 15...

Page 17: ...Box 120 0 03230 9 Thermostat w with B Bracket 500 0 05568 10 Bracket G Gas C Control V Valve 225 2 22095 10A Cover G Gas C Control V Valve 225 2 22096 11 Bracket T Thermostat 220 0 05493 12 Valve P P...

Page 18: ...e d date o of p purchase b by the e end u user Warranty is automatic if a component is found defective within 12 months of the date code marked on the part If the defect occurs more than 12 months lat...