5

For framing dimensions, refer to rough-in opening height and width shown in the specifications above.

Position the fan for desired airflow. Air will discharge on the side of the fan facing the propeller.

Assure the fan is fastened securely in the opening to avoid excess “rattling” or vibration using proper fasteners. 

Fasteners not included.

Refer to motor nameplate for wiring diagram.

Fan Installation

CAUTION

BEFORE OPERATING YOUR NEW FAN, CHECK BLADE FOR PROPER TORQUE, CHECK ALL 

FASTENERS FOR TIGHTNESS AND ASSURE SCREENS AND/OR SHUTTERS ARE SECURELY 

IN PLACE.

Periodic maintenance schedules should be set to assure reliability and performance of the fan. This maintenance 

should included inspection of all fasteners, propeller torque and proper cleaning of the complete fan assembly.

Check for excessive vibration while fan is running.

Periodically inspect and tighten all set screws and hardware.

Assure all mounting hardware, chains, etc. are properly secured.

Motors feature permanently sealed ball bearings and require no further lubrication.

The fan propeller should be periodically cleaned to assure proper balance and performance.

Maintenance

Summary of Contents for 24D370

Page 1: ...ORLD PROVIDER INNOVATIVE CLIMATE SOLUTIONS 411 Mason Street Onalaska WI 54650 800 345 7200 608 783 5691 608 783 6115 fax www lbwhite com Congratulations Your new L B White galvanized box fan incorpora...

Page 2: ...com Owner s Manual Galvanized Box Fans 2 TABLE OF CONTENTS Specifications 4 Performance 4 Fan Installation 5 Maintenance 5 Troubleshooting Guide 6 Service Parts Identification Schematic 7 Replacement...

Page 3: ...Y DEATH OR PROPERTY DAMAGE MAKE SURE THE ELECTRICAL POWER SOURCE CONFORMS TO THE REQUIREMENT OF THE FAN S AS WELL AS LOCAL CODES ELECTRICAL CONNECTIONS INSTALLATION AND MAINTENANCE MUST BE DONE BY QUA...

Page 4: ...56x20x58 Performance CFM CFM Watt Model HP F L A Volt Ph Hz Motor RPM 0 00 SP 0 05 SP 0 10 SP 0 15 SP 0 00 SP 0 05 SP 0 10 SP 0 15 SP Db 0 00 SP 24D370 1 2 5 6 2 8 115 230 1 60 1100 5 618 5 192 4 845...

Page 5: ...K BLADE FOR PROPER TORQUE CHECK ALL FASTENERS FOR TIGHTNESS AND ASSURE SCREENS AND OR SHUTTERS ARE SECURELY IN PLACE Periodic maintenance schedules should be set to assure reliability and performance...

Page 6: ...y anchored 4 Bad noisy bearings 1 Free blade of obstruction 2 Replace blade 3 Secure properly 4 Replace motor Insufficient airflow 1 Incorrect voltage applied 2 Defective motor 3 Propeller is damaged...

Page 7: ...CLIP SC CLIP SC CLIP SC CLIP SC CLIP SC 4 Motor B370 6E B370 8E B370 8E B370 8TE A750 8VE A750 8TVE 5 Upright frame piece N A N A N A N A N A N A 6 Side panel piece N A N A N A N A N A N A 7 Locking n...

Page 8: ...ncluding any implied warranties or merchantability or fitness for a particular purpose are expressly disclaimed In the event any implied warranty is not hereby effectively disclaimed due to operation...