background image

1.

Re a d   a l l   s a fe t y   p r e c a u t i o n s   a n d   fo l l ow   P S I
recommendations when using this torch. If you
suspect that a part is damaged or defective, call a
qualified service agency for repair or replacement.

2.

The torch’s gas pressure regulator (with pressure
relief valve) must be protected from adverse weather
conditions (rain, ice, snow) as well as from building
materials (tar, concrete, plaster, etc.) which can affect
safe operation and could result in property damage or
injury.

3.

Check all connections for gas leaks.  Gas leak testing
is performed as follows:

-- In the event a gas leak is detected, check the

components involved for cleanliness and
proper application of pipe compound before
further tightening.

-- Fu r t h e r   t i g h te n   t h e   g a s   c o n n e c t i o n s   a s

necessary to stop the leak.

-- After all connections are checked and any

leaks are stopped, wait at least 5 minutes to
allow gas to dissipate.

-- Light the torch.

-- W i t h   t h e   to rc h   i n   o p e r a t i o n ,   c h e c k   a l l

connections, hose connections, fittings and
joints with approved gas leak detectors.

-- If a leak is detected, check the components

involved for cleanliness in the thread areas
and proper application of pipe compound
before further tightening.

-- Tighten the gas connection as necessary to

stop the leak.

-- If necessary, replace the parts or components

involved if the leak cannot be stopped.

-- Ensure all gas leaks have been identified and

repaired before proceeding.

4.

A qualified service agency must check for proper
operating gas pressure upon installation of the torch.

5.

Light according to instructions within owner's manual.

6.

Model 161-D (cast head) torches must have the
proper gas regulator for the application.  Use only the
L.B. White regulator originally supplied with the torch.
The regulator supplied with this torch includes a POL
fitting incorporating an excess flow valve. Model 172-
D (steel head) torches include a POL fitting with
excess flow valve for direct connection to the gas
supply without use of a regulator.  Regardless of torch
model, the excess flow valve is a safety device which
protects against discharge from the propane gas
supply container if the POL is broken off from the
torch when in operation.  If the POL fitting is ever
replaced, it needs to be replaced with an L.B. White
POL fitting.  Failure to do so can result in fires,
explosions, loss of property, injury or death.

7.

This torch is configured for use for propane vapor
withdrawal only.  Do not use the torch in a propane
liquid withdrawal system or application.  If you are in
doubt, contact L.B.White Company.

8.

Take time to understand how to operate and maintain
the torch by using this Owner’s Manual.  Make sure
you know how to shut off the gas supply to the torch.
Contact your fuel gas supplier if you have any
questions.

9.

Any defects found in performing any of the service or
maintenance procedures must be eliminated and
defective parts replaced immediately.  The torch must
be retested by properly qualified service personnel
before placing it back into use.

10.

Open the gas supply valve slowly to prevent lock up of
the excess flow valve within the POL fitting. If opened
quickly, lock-up may occur, and gas supply will be
blocked. To correct this, close the fuel supply valve
and wait about 1 minute for the flow device to reset
itself.

14.

Propane gas supply containers have left handed
threads.  Always use the appropriate wrench to make
a connection to tighten or loosen the P.O.L. fitting at
the container’s gas supply valve.

15.

Always use pipe thread compound that is resistant to
propane and natural gas when making threaded
connections.

16.

The components on the torch that call for hand
operation should work with hand pressure only.  If
more force is required, have a qualified gas heater
service agency replace the defective part.  Do not
attempt to repair.

7

User Instructions

GENERAL

WARNING

Fire and Explosion Hazard

Do not use open flame (matches, candles, etc.) in
checking for gas leaks.

Use only approved leak detectors.

Failure to follow this warning can lead to fires or
explosions.

Fires or explosions can lead to property damage,
personal injury or loss of life.

Summary of Contents for 161-D

Page 1: ...held torch intended for temporary use in industrial farm or construction applications where strong direct localized heat is required If you are considering using this torch for any applications other than its intended use then please contact your fuel gas supplier or L B White Co Inc 150 29473 MODEL OUTPUT Btuh FUEL 161 D Cast Head 500 000 172 D Steel Head Owner s Manual and Instructions Hand Held...

Page 2: ...s can lead to property damage personal injury or loss of life GENERAL HAZARD WARNING Failure to comply with the precautions and instructions provided with this torch can result in Death Serious bodily injury or burns Property damage or loss from fire or explosion Asphyxiation due to lack of adequate air supply or carbon monoxide poisoning Read this Owner s Manual before installing or using this pr...

Page 3: ...age 6 for definition of the necessary qualifications Contact your local L B White distributor or L B White Co for assistance or if you have any questions about the use of the equipment or its application L B White Company has a policy of continuous product improvement It reserves the right to change specifications and design without notice SECTION PAGE General Information 3 Heater Specifications 4...

Page 4: ...50 100 lb cylinders Fuel Consumption Per Hour lbs 23 2 6 ft 1 83 m 161 D CAST IRON HEAD 7 15 T172 D STEEL HEAD 5 45 SPECIFICATIONS Model Ventilation Air Required to Support Combustion CFM Net Weight lbs Includes Gas Connection Components Minimum Safe Distance From Propane Gas Supply Container Inlet Gas Supply Pressure Required at the Torch Inlet PSIG ...

Page 5: ... the intensity of its odor can fade under some circumstances If there is an underground leak the movement of gas through the soil can filter the odorant Propane LP gas odor may differ in intensity at different levels Since propane LP gas is heavier than air there may be more odor at lower levels Always be sensitive to the slightest gas odor If you continue to detect any gas odor no matter how smal...

Page 6: ...age to torch components leading to property damage 7 The hose assembly shall be visually inspected on a daily basis after torch relocation and when the torch is in use If it is evident there is excessive abrasion or wear or if the hose is cut it must be replaced prior to the torch being put into operation The hose assembly shall be protected from building materials and contact with hot surfaces du...

Page 7: ...egulator Regardless of torch model the excess flow valve is a safety device which protects against discharge from the propane gas supply container if the POL is broken off from the torch when in operation If the POL fitting is ever replaced it needs to be replaced with an L B White POL fitting Failure to do so can result in fires explosions loss of property injury or death 7 This torch is configur...

Page 8: ... with a male nut and stem called a POL Remove the cap from the POL Insert POL stem into the valve on the propane gas supply Thread the nut counterclockwise into the propane supply valve Tighten the nut securely with a wrench See Fig 4 2 Slowly open the tank valve This will prevent lock up of the excess flow valve within POL stem 3 Check all connections with approved leak detector Do not use flame ...

Page 9: ... are found replace the hose immediatley do not attempt repair 3 Regulators must be periodically inspected to make sure the regulator vents are not blocked Debris insects insect nests snow or ice on a regulator can block vents and cause excess pressure at the torch 4 Regulators can wear out and function improperly Have your gas supplier check the date codes on all regulators installed and check del...

Page 10: ...r Insufficient size or quantity of propane supply containers D COMPLETION 1 Once the proper pressure has been confirmed close fuel supply valve 2 After allowing heater to burn off fuel remaining in gas hose close manual valve on torch 3 Remove gauge and install plug into regulator tightening securely Check for gas leaks Service Instructions 10 Close the fuel supply valves to the torch and allow th...

Page 11: ...ck valve in POL fitting Close fuel supply valve and wait a minute to allow is locked allow check valve to reset itself Open container valve slowly Burner Component used to channel gas air mixture and provide an area at which the fuel may ignite Burner Orifice Brass metering device used to feed gas to the burner at a specific rate Gas Hose Flexible connector used to convey gas from gas supply to to...

Page 12: ...onths of the date code marked on the part If the defect occurs more than 24 months later than the date code but within 24 months from the date of purchase by the end user a copy of a bill of sale will be required to establish warranty qualification The warranty set forth above is the exclusive warranty provided by L B White and all other warranties including any implied warranties or merchantabili...