Rigging procedures
Flying with a U-bracket
type of deployment
ying
rigging accessories
X-US1215 or X-UL12
additional material
truss clamp
min number of operators
1
Additional safety for own arrays
When ying an enclosure or an array, use the M8 DIN580 threaded insert to implement a secondary safety.
The procedure is shown with X-US1215.
The same procedure applies for X-UL12.
Assembly
Procedure
1.
Drive the knobs in the inserts on the enclosure.
Stop when the threading is halfway in.
2.
Place the U-bracket around the assembly.
Adjust the knobs on both sides so that the safety washer is between the hook and the enclosure.