Rigging procedures
Rigging procedures
Mounting on a U-bracket
wall-mounting
type of deployment
ceiling-mounting
rigging accessories
X-US1215 or X-UL12
3 x M10 screws
additional material
electric screwdriver
min number of operators
1 or 2
Additional safety for own arrays
When ying an enclosure or an array, use the M8 DIN580 threaded insert to implement a secondary safety.
Ceiling-mounting
Additional holes on the short U-bracket can be used for optimal visual impact.
In this case, the rigging procedure will require 2 operators.
Short U-bracket in horizontal position
In this position, the enclosure applies a diagonal force of
405 daN
on the anchoring points.
Fasteners for wall-mounting or ceiling-mounting
Secure the bracket with three M10 screws.
Select screw length and anchors applicable to the wall or ceiling properties.
The procedure is shown with X-UL12 in horizontal position.
The same procedure applies for X-UL12 in vertical position or in ceiling-mounting conguration and X-US1215 in
horizontal or vertical position or in ceiling-mounting conguration.
Assembly
Procedure
1.
Drive the knobs in the inserts on the enclosure.
Stop when the threading is halfway in.