Inspection and preventive maintenance
Rigging check
Active check of the stacking mechanism of Syva. Refer to the
(p.44) for further rigging
instructions, screwdriver bits, and Torque.
Procedure
1.
Remove the protection plate and inspect the mechanical interface.
magnet (x4)
lodging (x4)
AutoConnect
• The lodgings are not worn out.
• The four magnets are present.
• The AutoConnect connector is not damaged.
• The mechanical interface is tightly secured to the cabinet.
2.
Stack Syva on top of Syva Low and Syva Base.
• The lodgings meet the studs.
3.
Gently push Syva from side to side.
• The assembly remains stable.