Mechanical safety
Mechanical safety
Flown congurations
The Syva rigging system complies with 2006/42/EC: Machinery Directive. It has been designed following the guidelines
of BGV-C1.
2006/42/EC: Machinery Directive species a safety factor of 4 against the rupture. The own deployments described in
this manual achieve a safety factor of
5 or more
.
Refer to Soundvision for the safety factor of a specic deployment.
The
safe limit
gives the maximum number of elements for which the safety factor is compliant with the 2006/42/
EC: Machinery Directive, within the use dened in this manual and regardless of the other deployment parameters (site
angles, inter-element angles, etc.).
The
maximum limit
gives the maximum number of elements for which the safety factor can be compliant with the
2006/42/EC: Machinery Directive, when the other deployment parameters provide the best mechanical conditions.
For mixed arrays refer to your Soundvision model.
Syva
conguration
rigging accessory
maximum / safe limit
Flown
Syva Bar
1
Wall-mounted
Syva Wall
1
Other congurations
For other congurations, respect the recommended maximum limit for optimal stability.
Syva
conguration
rigging accessory
maximum / safe limit
Ground-stacked
Syva Base
1
Pole-mounted
Syva Pole
1
Syva Low / Syva Sub
conguration
rigging accessory
maximum / safe limit
Ground-stacked
Syva Base
1
Ground-stacked
No rigging accessory
1
Syva on Syva Low
conguration
rigging accessory
maximum / safe limit
Ground-stacked
Syva Base
1
Syva owner's manual (EN) version 1.0
23
Summary of Contents for S Series