MTD 112
35
06/97
When arraying a large number of subwoofers, they can become overdirective even at very
low frequencies. Using a delay unit for the signal feeding the outermost enclosures can
provide an accurate control of the directivity, and is therefore recommended.
- Side-Fill applications
For side-fill applications, the MTD 112 will be simply located on top of a floor-standing SB
115. The configuration key selection switch on the controller will be "X.OVER".
6.5 PHASE CHECK
A phase check of every installation must be performed. This shall be done with a polarity
checking system, like, for instance, the SCV PC 80 MKII.
This system comprises two devices, a generator and a receiver. The checking procedure is
as follows:
1 Generator
a) disconnect one output of the mixing desk, and replace it by the output of the PC 80
generator.
b) the PC 80 generator should be switched on "HOT PIN 2"
Summary of Contents for MTD 112
Page 1: ...MTD 112 OWNER MANUAL ...
Page 12: ...MTD 112 11 06 97 3 2 STEREO F O H WITHOUT SUB a 2 MTD 112 ...
Page 13: ...MTD 112 12 06 97 b 4 MTD 112 ...
Page 14: ...MTD 112 13 06 97 3 3 STEREO F O H WITH SUB a 2 MTD 112 1 MTD 118 ...
Page 15: ...MTD 112 14 06 97 b 4 MTD 112 1 SB 218 ...
Page 16: ...MTD 112 15 06 97 3 4 3 SOURCES F O H WITH SUB ...
Page 17: ...MTD 112 16 06 97 3 5 3 SOURCES F O H WITHOUT SUB ...
Page 18: ...MTD 112 17 06 97 3 6 SIDE FILL ...
Page 20: ...MTD 112 19 06 97 c 2 Impedance amplitude phase response c 3 Polar response For 0 horizontal ...
Page 21: ...MTD 112 20 06 97 For 0 vertical c 4 Total harmonic distortion V 2 83V ...
Page 27: ...MTD 112 26 06 97 5 1 THE MTD 112 ENCLOSURE a External description 5 FEATURES ...
Page 39: ...MTD 112 38 06 97 7 3 MTD 112 LLCa SCHEMATICS ...