4.1 THE MTD 112 ENCLOSURE
a) Technology
The technology of the MTD 112 is based on the two-way dual concentric type. The flare of
the L.F. cone loads directly the H.F. compression driver, hence allowing a true coaxial
axisymmetry of the wavefront generated both by the L.F. and H.F. drivers.(This is not the
case when a small horn is fitted inside the L.F. driver, the L.F. wavefront being splitted near
the cutoff frequency, producing off-axis cancellations).
The L.F. driver is of the 12" standard with a 4" flat wire copper voice coil.
The H.F. driver is of the 2" exit standard, reduced to 13/8 at the output of the phase plug.
The voice coil is of the 3" standard, and the diaphragm is made of titanium alloy. There is
provided a conical aluminum flare matching the internal vent of the driver magnet to achieve
a smooth continuity of the wave path to the edge of the L.F. cone.
The same magnet is used for the H.F. and L.F. drivers, being provided with two opposite air
gaps.
b) Specifications
Frequency response:
65 Hz - 18 kHz +/- 3 dB.
Nominal impedance:
8 Ohms on both ways
Minimum recommended amplification
300 Watts
Continuous maximum S.P.L. @ 1 m.
122 dB.
(measured in half-space, pink noise)
Nominal directivity
90°, conical
c) Measured frequency responses
c-1 : Amplitude/Frequency response (1m, input=2.83V )
.
4. TECHNOLOGY & SPECIFICATIONS
Front
Monitor
X-Over
Summary of Contents for MTD 112
Page 1: ...MTD 112 OWNER MANUAL ...
Page 12: ...MTD 112 11 06 97 3 2 STEREO F O H WITHOUT SUB a 2 MTD 112 ...
Page 13: ...MTD 112 12 06 97 b 4 MTD 112 ...
Page 14: ...MTD 112 13 06 97 3 3 STEREO F O H WITH SUB a 2 MTD 112 1 MTD 118 ...
Page 15: ...MTD 112 14 06 97 b 4 MTD 112 1 SB 218 ...
Page 16: ...MTD 112 15 06 97 3 4 3 SOURCES F O H WITH SUB ...
Page 17: ...MTD 112 16 06 97 3 5 3 SOURCES F O H WITHOUT SUB ...
Page 18: ...MTD 112 17 06 97 3 6 SIDE FILL ...
Page 20: ...MTD 112 19 06 97 c 2 Impedance amplitude phase response c 3 Polar response For 0 horizontal ...
Page 21: ...MTD 112 20 06 97 For 0 vertical c 4 Total harmonic distortion V 2 83V ...
Page 27: ...MTD 112 26 06 97 5 1 THE MTD 112 ENCLOSURE a External description 5 FEATURES ...
Page 39: ...MTD 112 38 06 97 7 3 MTD 112 LLCa SCHEMATICS ...