Electro-acoustical description
Electro-acoustical description
Adjustable ns
A10 Focus and A10 Wide feature L-Fins to adjust the waveguide directivity to one of four settings: 110° / 70° symmetric
or 90° asymmetric (35°/55° or 55°/35°).
The same [A10] preset drives all directivity settings of both enclosures.
Within a line source, combine A10 Focus and A10 Wide with custom directivity settings to improve SPL mapping and
throw capability.
110° setting
5
5°
55°
12
A10 owner's manual (EN) version 1.1