Multi-Image Splicing Processor
14
3.4 Function key:
Brief explanation of function key:
INFO:
Information query key. Click this key and enter into its interface showing whether all
signal sources are inputting normally. Its interface is shown as below. Red light means signal is
lost while green one shows signal is normal.
WIN:
Image key. Click this key to enter into its interface and signal source selection can be
made in following interface. Taking image 3 as instance, click “WIN” to enter into image switch
interface which shows current signal sources of three images. If signal source switch is needed,
rotate the knob first to select the image and switch by “S1-S6” of the front panel.
OUT:
Output condition key. Click the key to enter into its interface with three output options:
blank screen, blue screen and normal screen. Selection of blank screen means all output interfaces
and large screen are blank; blue screen means all those are blue; and normal screen refers to
normal image output.
Information-Signal Condition
Image Switch
Image 1
S1
Image 2
S1
Image 3
S1