2
4 Case explanation
4.1 Horizontal splicing
For example:
P3 display, the resolution of the large screen is 5120 wide and 1024 high. It is
required that the large screen can display one screen or four screens, and each screen is a different
signal source. The client requires a point-to-point display in order to show the effect.
5120
1024
1280
1280
1280
1280
1024
Preparation:
4K dual graphics card with a custom resolution of 2560 × 1024 graphics card
for horizontal splicing. Desktop computer with DVI output port, laptop computer with HDMI output
port, laptop computer with VGA output port, high-definition camera with SDI output port. Input all
communication input signals to the corresponding input ports of the splicer.
Quick commissioning
:
1. Device mode: Select real-time mode.
2. splicing mode: Select horizontal splicing.
3. Output resolution: select 1280 × 1024.
4. Screen parameters: 4 output ports are horizontal size 1280 vertical size 1024.
5. Screen layout: Select layout two. MAIN screen and PIP-1 screen select the corresponding
signal source DP-1 / DP-2.
Note: The operation of selecting a signal source for a layer is to first click the corresponding
layer button, and then click the signal source button to be switched.
6. Single screen point-to-point display debugging is completed. Select the "MENU" menu key
to return to the main menu, select“Shift”+“
Save
Preset
”button
,
Enter the save preset interface and confirm
the save to mode 1.
7. Select the "MENU" menu key to return to the main menu and select screen layout layout 4.
Enter the corresponding layer setting interface to adjust the image size and position corresponding
to each layer. Select the "Shift+“
Save
Preset
" button to save to Mode 2.
8. Equipment debugging is complete