7-4 INPUT/OUTPUT RESISTANCE MODE 

 

a)  Measuring range  0 to 2000 Ω 

b)  Display accuracy  ±(0.2% of r 5 Ω) 

c)  Display 

When less than 400 Ω: Displays 1 

decimal place. 

When 4000 Ω or larger: No decimal 

place. 

d)  Connection check function 

 

 

When the input/output resistance is 10 Ω or less, 

buzzer sounds. 

(When the buzzer is set to ON.) 

 

7-5 INSULATION RESISTANCE MODE 

 

a)  Measuring range 

0 to 300 MΩ 

b)  Applied voltage 

Approx. 20 VDC 

c)  Display accuracy 

Within ±(15% of r 10 Ω) 

d)  Insulation check function 

 

 

When  the  insulation  resistance  is  less  than  100  MΩ, 

buzzer sounds. 

(When the buzzer is set to ON.) 

 

 

 

7-6 STRAIN OUTPUT MODE 

 

a)  Strain output value 

0.000 to ±5.000 mV/V 

(Step: 0.005 mV/V) 

0 to ±10000 µm/m 

(Step: 10 µm/m) 

b)  Input bridge excitation  12 VDC or less 

c)  Carrier frequency range  1k Hz to 28k Hz 

d)  Output accuracy 

 

 

For DC amplifier 

 

 

 

Within ±(0.5% of the set value + 0.020) mV/V 

Within ±(0.5% of the set value + 40) µm/m 

 

For carrier type amplifier 

 

 

Within ±(5% of the set value + 0.020) mV/V 

Within ±(5% of the set value + 40) µm/m 

e)  Input/output resistance  Approx. 350 Ω 

 

7-7 TEDS DATA DISPLAY MODE 

 

a)  Display contents 

 

 

 

Type, KYOWA original serial No., rated capacity, 

unit, rated output, input resistance, serial No. of the 

TEDS format 

 

 

8. DIMENSIONS 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

 

 

 

 

 

 

 

 

 

 

WDS-500BE-0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WDS-500BE-1 

 

TO

AMP

TO

SENSOR

SET

AUTO

MEAS

TEDS

ZERO

FUNC

STRAIN

MEAS

I/O

R

INSU

R

STRAIN

OUT

SENSOR CHECKER

O

N

O

FF

TO

AMP

TO

SENSOR

SET

AUTO

MEAS

TEDS

ZERO

FUNC

STRAIN

MEAS

I/O

R

INSU

R

STRAIN

OUT

SEN SOR C HECKER

O

N

O

FF

Summary of Contents for WDS-500BE

Page 1: ...y liquid from the batteries comes in contact with your skin wash quickly with water 11 The AA size alkaline batteries are primary batteries Do not recharge the alkaline batteries 12 Do not operate the WDS 500BE in environment with excessive moisture dust or oil dust Or electric shock or fire hazard may result 13 Do not disassemble the WDS 500BE Or deterioration or malfunction of the instrument may...

Page 2: ... the bridge excitation Black D side of the bridge output Green E Shield wire WDS 500BE 1 Applicable connector 3RT01 PE7M 1 side of the bridge excitation Red 2 Shield wire 3 side of the bridge output Green 4 No connection 5 side of the bridge excitation Black 6 No connection 7 side of the bridge output White Do not connect the WDS 500BE to the amplifier having bridge excitation voltage 12 V or more...

Page 3: ...splay language to English F 4 Contrast Initial Value 6 Every time the key is pressed the contrast changes Set from 0 to 15 After determine the contrast press the SET key Set display contrast F 5 Every time the key is pressed Set auto power Auto Power OFF Initial Value 00 the auto power OFF time changes Set from 00 to 99 After determine the auto power off time press the SET key 00 does not activate...

Page 4: ... output value 0 000 to 5 000 mV V Step 0 005 mV V 0 to 10000 µm m Step 10 µm m b Input bridge excitation 12 VDC or less c Carrier frequency range 1k Hz to 28k Hz d Output accuracy For DC amplifier Within 0 5 of the set value 0 020 mV V Within 0 5 of the set value 40 µm m For carrier type amplifier Within 5 of the set value 0 020 mV V Within 5 of the set value 40 µm m e Input output resistance Appr...

Reviews: