background image

 

PP-T-008-003D 

WDS-500BE SENSOR CHECKER INSTRUCTION MANUAL 

Thank you for purchasing KYOWA’s product. Read this 

Instruction Manual before using the WDS-500BE Sensor 

Checker (hereinafter referred to as the WDS-500BE). 

In addition, be sure that the Instruction Manual is ready for 

use at any time. 

SAFETY PRECAUTIONS 

This Instruction Manual describes detailed instructions for 

operating the WDS-500BE. 

For safe use of the WDS-500BE, do not forget to read the 

“Safety Precautions” prior to use. 

Kyowa Electronic Instruments Co., Ltd. assumes no liability 

for any damages resulting from user’s failure to comply with 

the safety precautions. 

For safety operation of the WDS-500BE, the following 

WARNING

” and “

CAUTION

” symbols are used in 

“Safety Precautions” of this Instruction Manual. 

In addition, items in         

CAUTION

 may lead to serious 

consequences. Take special attention to the Safety Symbols. 

The following symbol is used in the WDS-500BE to call 

operator’s attention when operating the product. 

 

 

 

 

1)  Installation and wiring work should be conducted more than 

3 seconds after the power is cutoff. Or, electric shock 

hazard or damage of the product may result. 

2)  Special care should be taken not to use the WDS-500BE in 

environment with inflammable gas or vapor. Or, fire hazard 

may result. 

3)  If the WDS-500BE is fault, emitting smoke or offensive 

odor, or producing abnormal sound, immediately turn OFF 

the power. Or, electric shock or fire hazard may result. 

Contact KYOWA or our representative for repair. 

4)  Do not put water or foreign matters into the WDS-500BE. 

In case if any foreign matters are entered, immediately turn 

OFF the power. Or, electric shock or fire hazard may result. 

Contact KYOWA or our representative for repair. 

5)  Always operate the WDS-500BE with the specified 

batteries. Or, electric shock or fire hazard may result. 

6)  Do not short-circuit positive (+) and negative (-) terminals 

of the batteries. Or, it may produce fever or ignite due to a 

rush current. 

7)  Do not heat the batteries or throw the batteries into fire. 

8)  Correctly insert batteries. 

9)  If liquid leaking from the batteries gets into your eyes, do 

not rub your eyes. Wash them well with clean water and 

consult with a doctor. 

10)  If any liquid from the batteries comes in contact with your 

skin, wash quickly with water. 

11)  The AA size alkaline batteries are primary batteries. Do not 

recharge the alkaline batteries.

 

12)  Do  not  operate  the  WDS-500BE  in  environment  with 

excessive  moisture,  dust  or  oil  dust.  Or,  electric  shock  or 

fire hazard may result. 

13)  Do  not  disassemble the  WDS-500BE.  Or,  deterioration  or 

malfunction of the instrument may result. 

 

 

 

1)  Before wiring, always confirm the rated power voltage of the 

WDS-500BE and terminal arrangement. Then, conduct 

wiring in the correct manner. 

2)  Special care should be taken when using the WDS-500BE in 

environment with excessive vibration. If the WDS-500BE is 

operated at a location with excessive vibration or with 

continuous vibration, it may cause measurement error and/or 

failure of the instrument. Take care not to drop it during 

transportation and avoid applying strong impact. 

3)  Basically, the WDS-500BE is designed to be used by 

connecting a strain gage transducer to the input terminal. Do 

not use transducers other than the above. Or, deterioration of 

the instrument may result. 

4)  Operate the WDS-500BE by conforming to operating 

environment specified in this Instruction Manual. Or, 

malfunction and/or failure of the instrument may result. 

5)  Operate the WDS-500BE by conforming to operating 

environment free from electrical stress such as overvoltage or 

electrostatic. Malfunction of the instrument may result. 

 

OUTLINE AND FEATURES 

 

•  The WDS-500BE is designed to check a strain gage 

transducer (hereinafter referred to as the transducer). The 

WDS-500BE is not measuring instrument. 

•  Capable of measuring strain of the transducer by one-touch 

key operation. 

•  Capable of outputting the equivalent signal to the transducer. 

•  Capable of measuring strain, input/output resistance, and 

insulation resistance automatically in automatic measuring 

mode. 

•  When connecting the WDS-500BE with the 

TEDS-compatible transducer, TEDS data is displayed. 

 

 

Improper operation of the system may result in 

death or severe injury of the operator. 

 

Improper operation of the system may result in 

injury of the operator and physical damage of the 

system. 

Safety Symbols used in the WDS-500BE 

 

Indicates “Handling Precautions.” This symbol is 

attached to the WDS-500BE when it requires to refer to 

the Instruction Manual for securing safety of the operator 

and the product. 

WARNING 

CAUTION 

WARNING 

CAUTION 

Summary of Contents for WDS-500BE

Page 1: ...y liquid from the batteries comes in contact with your skin wash quickly with water 11 The AA size alkaline batteries are primary batteries Do not recharge the alkaline batteries 12 Do not operate the WDS 500BE in environment with excessive moisture dust or oil dust Or electric shock or fire hazard may result 13 Do not disassemble the WDS 500BE Or deterioration or malfunction of the instrument may...

Page 2: ... the bridge excitation Black D side of the bridge output Green E Shield wire WDS 500BE 1 Applicable connector 3RT01 PE7M 1 side of the bridge excitation Red 2 Shield wire 3 side of the bridge output Green 4 No connection 5 side of the bridge excitation Black 6 No connection 7 side of the bridge output White Do not connect the WDS 500BE to the amplifier having bridge excitation voltage 12 V or more...

Page 3: ...splay language to English F 4 Contrast Initial Value 6 Every time the key is pressed the contrast changes Set from 0 to 15 After determine the contrast press the SET key Set display contrast F 5 Every time the key is pressed Set auto power Auto Power OFF Initial Value 00 the auto power OFF time changes Set from 00 to 99 After determine the auto power off time press the SET key 00 does not activate...

Page 4: ... output value 0 000 to 5 000 mV V Step 0 005 mV V 0 to 10000 µm m Step 10 µm m b Input bridge excitation 12 VDC or less c Carrier frequency range 1k Hz to 28k Hz d Output accuracy For DC amplifier Within 0 5 of the set value 0 020 mV V Within 0 5 of the set value 40 µm m For carrier type amplifier Within 5 of the set value 0 020 mV V Within 5 of the set value 40 µm m e Input output resistance Appr...

Reviews: