Laryngeal mask ventilation
Intraoral Intubation with Laryngoscope
3
4
9
Training
Training skills
Setting the head at "sniffing position", intubation
with laryngoscope can be performed.
Put enough lubricant to the model before inserting the tracheal tube.
For nasotracheal airway, spray the lubricant in the cavitas nasi and the tube. For oral route airway,
in the mouth and the tube.
Put enough lubricant to the laryngeal mask and the oral cavity before training.
Recommended laryngeal mask:
LMA
i-gel
Caution
Caution
4
4
type
size
The upper incisors are removable with excess
force.
Recommended tools: Macintosh laryngoscope Size: No.3
Tracheal tube: 7.0, 7.5 mm (inside diameter)
Use the lubricant included in the set. Others like gel type may remain in the model
and become irremovable.