Unpacking
KEW 2062/2062BT
- 3 -
KEW 2062/2062BT
Unpacking
We thank you for purchasing our clamp power meter KEW 2062 / KEW2062BT.
Please check that the following accessories are packed with the instrument.
[Basic package]
1
Clamp power meter
KEW 2062 / KEW 2062BT : 1 pce.
2
Test leads
MODEL7290: 1 set
* Red, black, and yellow: 1 pce. each with alligator clips
3
Batteries
Alkaline size AA battery (LR6) x 2 pcs.
4
Instruction manual
: 1 pce.
5
Soft case
MODEL9198
: 1 pce.
●
In case any of the items listed above are found to be damaged or missing or if the printing
is unclear, please contact your local KYORITSU distributor.
Safety precautions
This instrument has been designed, manufactured and tested according to IEC 61010:
Safety requirements for Electronic Measuring apparatus, and delivered in the best condition
after passing quality control tests.
This instruction manual contains warnings and safety procedures which have to be
observed by the user to ensure safe operation of the instrument and to maintain it in safe
condition. Therefore, read through these operating instructions before starting to use the
instrument.
WARNING
● Read through and understand the instructions contained in this manual before using the
instrument.
● Keep the manual at hand to enable quick reference whenever necessary.
● The instrument is to be used only in its intended applications.
● Understand
and follow all the safety instructions contained in the manual.
It is essential that the above instructions are adhered to. Failure to follow the above instructions
may cause injury, instrument damage and/or damage to equipment under test. Kyoritsu assumes
no responsibility for damage and injury caused by misuse or not following the instructions in the
manual.
The symbol
indicated on the instrument, means that the user must refer to the related
parts in the manual for safe operation of the instrument. It is essential to read the
instructions wherever the symbol appears in the manual.
DANGER : is reserved for conditions and actions that are likely to cause serious or fatal
injury.
WARNING : is reserved for conditions and actions that can cause serious or fatal injury.
CAUTION : is reserved for conditions and actions that can cause injury or instrument
damage.
KEW 2062/2062BT
Safety precautions
KEW 2062/2062BT
- 4 -
Meaning of symbols on the instrument:
User must refer to the explanations in the instruction manual.
Instrument with double or reinforced insulation
This instrument can clamp a bare conductor where the voltage
to be measured is lower than the circuit – voltage against earth
values specified by the marked measurement category.
AC (Alternating current)
(Functional) Earth terminal
This instrument satisfies the marking requirement defined in the
WEEE Directive (2002/96/EC). This symbol indicates separate
collection for electrical and electronic equipment.
Measurement Category
To ensure safe operation of measuring instruments, IEC 61010 establishes safety standards
for various electrical environments, categorized as O to CAT IV, and called measurement
categories. Higher-numbered categories correspond to electrical environments with greater
momentary energy, so a measuring instrument designed for CAT III environments can
endure greater momentary energy than one designed for CAT II.
O
: Circuits which are not directly connected to the mains power supply.
CAT II : Electrical circuits of equipment connected to an AC electrical outlet by a power cord.
CAT III : Primary electrical circuits of the equipment connected directly to the distribution panel,
and feeders from the distribution panel to outlets.
CAT IV : The circuit from the service drop to the service entrance, and to the power meter and
primary overcurrent protection device (distribution panel).
~
www.
.com
1.800.561.8187