background image

 다기능 디지털 복합 보호계전기

 

K-PAM 5500 Series

4

5

Kyongbo Electric Co., Ltd.

Digital Integrated Protection Relay

 

K-PAM 10 Series

MEASUREMENT

RECORDS

STATUS

DEVICE CONFIG

SYSTEM INFO

MENU

VOLTAGE

OCR1

DOCGR

UVR3

PROT STATUS

FREQUENCY

EVENT LIST

POWER

OCR3

OVR1

OVGR2

D/I STATUS

CT RATIO

EVENT CLEAR

FREQUENCY

OCGR2

OVR3

DPR2

R/I STATUS

CIRCUIT BREAKER

CURRENT

OCR2

SGR

OVGR1

CB STATUS

VT RATIO

FAULT LIST

ENERGY

OCGR1

OVR2

DPR1

D/O STATUS

ZCT RATIO

FAULT CLEAR

ENERGY CLEAR

OCGR3

UVR2

UVR1

UPR1
UPR2

CB/DO COUNT

POWER SYSTEM

RELAY SETTING

RELAY SETTING

MEASUREMENT

RECORDS

STATUS

POWER SYSTEM

DEVICE CONFIG

SYSTEM INFO

MENU

OVR1

OVGR1

UFR2

PROT STATUS

FREQUENCY

OVR3

NSOVR

D/I STATUS

EVT RATIO

FAULT LIST

UVR2

OFR1

R/I STATUS

REV CON DETECTOR

VOLTAGE DETECTOR

FAULT CLEAR

FREQUENCY

OVR2

OVGR2

ROCOF

CB STATUS

VT RATIO

EVENT LIST

UVR1

POR

D/O STATUS

PHASE ROTATION

EVENT CLEAR

VOLTAGE

UVR3

UFR1

OFR2

CB/DO COUNT

CIRCUIT BREAKER

RELAY SETTING

MENU

VOLTAGE

PROT STATUS

FREQUENCY

OCR1

DOCGR2

OVGR2

REMOTE INPUT #7

EVENT LIST

POWER

D/I STATUS

CT RATIO

OCR3

OVR2

REMOTE INPUT #1

DPR2

REMOTE INPUT #9

LED #1

DIGITAL OUTPUT #2

LEDS

EVENT CLEAR

FREQUENCY

R/I STATUS

NCT RATIO

OCGR2

UVR1

REMOTE INPUT #3

 UPR2

REMOTE INPUT #11

LED #3

DIGITAL OUTPUT #4

RS-485

REV CON DETECTOR

DOCR2

UVR3

REMOTE INPUT #5

OFR2

REMOTE INPUT #13

LED #5

UFR2

REMOTE INPUT #15

LED #7

D/O TEST

DIGITAL INPUT #2

VOLTAGE DETECTOR

WAVE RECORDS

SYSTEM STATUS

TEST

DIGITAL INPUTS

CURRENT

CB STATUS

VT RATIO

OCR2

OVR1

DPR1

REMOTE INPUT #8

ALARM

DIGITAL OUTPUT #1

REMOTE INPUTS

FAULT LIST

ENERGY

D/O STATUS

EVT RATIO

OCGR1

OVR3

REMOTE INPUT #2

 UPR1

REMOTE INPUT #10

LED #2

DIGITAL OUTPUT #3

TIME SET

FAULT CLEAR

ENERGY CLEAR

CB/DO COUNT

PHASE ROTATION

DOCR1

UVR2

REMOTE INPUT #4

OFR1

REMOTE INPUT #12

LED #4

DIGITAL OUTPUT #5

DEVICE ID

TIME

FAULT RESET

CIRCUIT BREAKER

DOCGR1

OVGR1

REMOTE INPUT #6

UFR1

REMOTE INPUT #14

LED #6

D/I TEST

DIGITAL INPUT #1

ROCOF

REMOTE INPUT #16

LED #8

PANEL TEST

DIGITAL INPUT #3

CURRENT DETECTOR

PASSWORD

VERSION

INIT DISPLAY

DIGITAL OUTPUTS

MEASUREMENT

RECORDS

STATUS

POWER SYSTEM

DEVICE CONFIG

SYSTEM INFO

  K-PAM 10Series Menu Configuration

※ DEVICE CONFIG and SYSTEM INFO are common to 10 Series.

■ DG10

■ S10

■ V10

Summary of Contents for K-PAM 10 Series

Page 1: ...K PAM 10 Series Digital Integrated Protection Relay User Manual...

Page 2: ...elay K PAM 10 Series K PAM10Seriesisamulti functionaldigitalIntegrated protection relay that provides high precision measurement and reliable protection relay function for power supply and distributio...

Page 3: ...E INPUT 7 EVENT LIST POWER D I STATUS CT RATIO OCR3 OVR2 REMOTE INPUT 1 DPR2 REMOTE INPUT 9 LED 1 DIGITAL OUTPUT 2 LEDS EVENT CLEAR FREQUENCY R I STATUS NCT RATIO OCGR2 UVR1 REMOTE INPUT 3 UPR2 REMOTE...

Page 4: ...O MENU OCR1 DOCGR2 OCR3 OVGR2 OCGR2 UBOCR OCR2 VOLTAGE CURRENT OVGR1 OCGR1 SGR DOCGR1 EVENT LIST EVENT CLEAR FAULT LIST FAULT CLEAR PROT STATUS D I STATUS R I STATUS CB STATUS D O STATUS CB DO COUNT C...

Page 5: ...a setting Right Key Used to move from the menu to the upper menu or to the right when setting Left Key Used to move from menu to sub menu or to move to the left when setting MENU Key Used to enter the...

Page 6: ...ntact Capacity AC 250V 5A DC 125V 10A 6 4a_NO 7 3_4_COM 8 5b_NC For System Error Contact Capacity AC 250V 5A DC 125V 1 9 5_COM 10 DI 1 User defined Input Contact 11 DI 2 12 DI 3 13 DI COM 14 RS 485 Se...

Page 7: ...t for details C I R C U I T B R E A K E R C O N T R O L E N T E R Y E S E S C N O C O N T R O L F A I L E D C B S T A T E D I S A B L E D If the front LOCAL REMOTE LED is lit as REMOTE pressing the L...

Page 8: ...P OP OP RST ALL EVENT record setting Category Setting Range Description FUNCTION DISABLED ENABLED Setting whether to use the function ID NAME 8 ASCII Characters Protection element name setting ALGORIT...

Page 9: ...REVERSE Operation direction setting MODE INST DT INV Operation mode setting TIME DELAY 0 04 60 00s 0 01s STEP Operation delay time setting CURVE IEC_NI IEEE_MI Inverse curve setting 12ea LEVER 0 01 1...

Page 10: ...00 60 00s 0 01s STEP Reset delay time setting UVR Setting Method After selecting UVR 27 in Protection Relay Element Setting Method press the RIGHT Key to enter the setting screen Use the UP DOWN KEY...

Page 11: ...position of the contact to be tested the contact will change from Off to On and the contact will be output When the ESC ESC key is pressed the output contact is reset 2 If you press the UP or DOWN KEY...

Page 12: ...T A T U S P K P O P 1 O C R 1 A B C 2 O C G R 1 3 D O C G R P R O T S T A T U S P K P O P 1 O C R 1 A B C A B C 2 O C G R 1 3 D O C G R P R O T S T A T U S P K P O P 1 O C R 1 A B C 2 O C G R 1 3 D O...

Page 13: ...voltage and frequency are 1 0 6 0 016 Hz and the frequency changed by 0 02Hz or more per at least 1 cycle is about 20 cycles about 0 3 sec for voltage A At this time the voltage should be at least 80...

Page 14: ...Terminal T1 D O4_NO D O3 4_COM D O2_NO D O2_COM Aux Power 1 2 Terminal T2 FG 3 CHASSIS V10 A L1 B L2 C L3 D O1_NO 1 2 3 4 5 6 7 8 9 14 15 16 COM RS 485 8 7 VN IA IB IC IN C L R EVT Terminal T1 D O1_C...

Page 15: ...rminal T2 FG 3 CHASSIS M11 9 10 11 12 13 14 15 16 CT A L1 B L2 C L3 D O1_NO 1 2 3 4 5 6 7 8 9 14 15 16 COM RS 485 1 2 VA 3 4 5 6 8 7 VB VC VN IA IB IC C L R EVT Terminal T1 D O1_COM D O3_NO D O5_NC D...

Page 16: ...bolts on the corners of the enclosure mounted on the panel Remove the handle cover of the product loosen the screw raise the handle vertically as shown in and attach it to the enclosure After inserti...

Page 17: ...K PAM 10 Series Digital Integrated Protection Relay User Manual...