Emergency Stop Safety Relay SR7C 

M03 

Ver. A 

E61-141-00 

Operating Instructions

 

English translation 

Errors and technical changes reserved 

The  SR7C is  a  universal  emergency  stop  safety  switching  device 
with seven safe relay outputs that can quickly and safely stop the 
moving parts of a machine or system in case of danger.  

Applications  for  the  SR7C  include  single or  dual-channel emer-
gency  stop  circuits  and  guard  monitoring on machines  and  sys-
tems.  

Function 

The  emergency  stop  safety  switching  device  SR7C  is 
designed  for  safe  isolation  of  safety  circuits  according  to 
EN 60204-1 and can be used up to safety category 4, PL e 
according to EN ISO 13849-1. 
The internal logical system closes the safety contacts when 
the start button is pressed. 
If  the  safety  switch  is  opened,  the  positively  driven  safety 
contacts are opened and safely switch the machine off. It is 
ensured  that  a  single  fault  does  not  lead  to  a  loss  of  the 
safety  function  and  that  every  fault  is  detected  by  cyclical 
self-monitoring  no  later  than  when  the  system  is  switched 
off and switched on again. 
The operating status of the device is indicate by the auxilia-
ry transistor outputs O1 and O2. 

O1: Ready. PWR is connected. 
O2: Both relay channel K1, K2 are switched on. 

Electrical 
Connection 

• 

Consider the information in the section "Techn. data" 

• 

A safe transformer according to IEC 61558-2-6 or a 
power supply unit with electrical isolation from the 
mains must be connected 

• 

External fusing of the safety contacts must be provided 

• 

If the device does not function after commissioning, it 
must be returned to the manufacturer unopened. Ope-
ning the device will void the warranty 

• 

Use adequate protective circuit for inductive loads (e.g. 
free-wheeling diode) 

Installation 

As per EN 60204-1, the device is intended for installation in 
control  cabinets  with  a  minimum  degree  of  protection  of 
IP54.  It  is  mounted  on  a  35  mm  DIN  rail  according  to                
DIN EN 60715 TH35. 

Safety 
Precautions 

Fig. 1 Block diagramm SR7C 

Fig. 2  Installation / removal 

Fig. 3  Connections 

A1:  

Power Supply 

A2 : 

Power Supplay 

S11:  

DC 24V  control voltage 

S10:  

Control line 

S12: 

Control line 

S13: 

Control line 

S14: 

Control line 

S21: 

Start, Control line 

O1;O2: 

Aux transistor outputs 

0V: 

Reference common O1, O2 

81-82: 

Auxiliary Contact 

91-92: 

Auxiliary Contact 

101-102:  Auxiliary Contact 
101-112:  Auxiliary Contact 
13-14 bis 73-74: 

 

 

Safety Out1-7 

 

• 

All relevant safety regulations and standards are to be 
observed. 

• 

The overall concept of the control system in which the 
device is incorporated must be validated by the user. 

• 

Failure to observe the safety regulations can result in 
death, serious injury and serious damage. 

• 

Note down the version of the product (see label “Ver: x”) 
and check it prior to every commissioning of a new de-
vice. If the version has changed, the overall concept of 
the control system in which the device is incorporated 
must be validated again by the user. 

• 

Installation and commissioning of the device must be 
performed 

only by authorized personnel

• 

Observe the country-specific regulations when installing 
the device. 

• 

The electrical connection of the device is only allowed to 
be made with the device isolated. 

• 

The wiring of the device must comply with the instruc-
tions in this user information, otherwise there is a risk 
that the safety function will be lost. 

• 

It is not allowed to open the device, tamper with the 
device or bypass the safety devices. 

• 

7 safe, redundant relay outputs 

• 

4 auxiliary relay and 2 auxiliary semiconductor outputs 

• 

Connection of: 

    -  Emergency stop buttons 
    -  Safety switches 
    -  Non-contact safety switches 
    -  OSSD-Outputs 

• 

Single or dual-channel operation possible 

• 

Feedback loop for monitoring downstream contactors or 
expansion modules 

• 

Cyclical monitoring of the output contacts 

• 

Indication of the swiching state via LED 

• 

2 start behavior possible: 

  -  Monitored manual start 
  -  Automatic start 

• 

Up to PL e, SILCL 3, category 4 

• 

STOP-category: 0 