background image

7

Troubleshooting 

Fault

Cause

Remedy

The machine does not run when the 

ON/OFF switch and spray handle lever 

are pressed.

The plug is damaged.

There is insufficient voltage.

The pump is locked.

The thermal relay has triggered.

Check the plug and fuses to see if they 

are okay.

Manually turn over the motor.

Let the motor cool down.

The machine runs, however only weak 

pressure is generated.

The intake filter is clogged.

Air is being drawn in at the connectors.

The inlet and outlet valves are clogged 

or worn.

The diameter of the nozzle hole is too 

large.

Clean the filter.

Check the intake connection fitting and 

the hose connectors.

Clean or replace.

Check and replace.

The operating pressure is irregular.

Air is being drawn in.

The valves are clogged and worn.

The seals are worn.

Check the intake connectors.

Clean and replace.

Check and replace.

The machine suddenly stops.

The thermal relay has triggered due to 

overheating.

Check the voltage.

Turn off the switch and let the motor 

cool down for a few minutes.

Water drop from connect pars.

The seals are worn.

Check and replace (professional repair 

shop)

There is a loss of pressure.

The nozzle is worn.

The valves are dirty or clogged.

The valve seals are worn.

The seals are worn.

The filter is clogged.

Change the nozzle.

Check, clean, exchange.

Check and /or exchange.

Check and /or exchange.

Check and /or clean.

There is excess noise.

Air is being drawn in.

The valves are worn, dirty or clogged.

The bearings are worn.

The water temperature is too high.

The filter is dirty.

Check intake lines.

Check, clean, exchange.

Check and /or exchange.

Lower the temperature to below 40

.

Check and /or exchange.

Expelled water is mixed with oil.

The sealing rings (water + oil) are worn. Check and /or exchange.

Water leaks from the pump head.

The seals are worn.

The O-ring of the seal set is worn.

Exchange the seal.

Exchange the O-ring.

When the switch is pressed, the motor 

hums but does not start.

The mains voltage is lower than that 

specified.

The pump is blocked or frozen.

The extension cable is insufficient (cross 

section too small, cable too long)

Check to see that the extension cable 

is sufficient.

Exchange the extension cable for one 

that is sufficient.

Discarding the machine

Carry out the following safety measures immediately, if you are no longer going to use the machine:

•  Pull out the plug and make the machine inoperable.

•  Store the machine in an area that cannot be reached by children.

•  Do not use any parts from the used machine as replacement parts.

•  Disassemble the machine and discard the individual parts in accordance with the regulation neforced in your area.

SAVE THESE INSTRUCTIONS

Summary of Contents for RYOBI AJP-800

Page 1: ...69800384 00 KAP 04 20 AJP 800...

Page 2: ...1 1 1 2 7 8 3 4 5 6 2 3 4 4 5 6 5 11 10 17 9 5 2 3 4 6...

Page 3: ...2 A B B A 7 10 14 2 13 4 5 18 8 6 16 17 10 7 6 12 15 4 5 2 3 9 3 4 7 8 9 11 10 12 15 14 13 16...

Page 4: ...ay Damaged parts must be immediately replaced by a qualified electrician Always pull the power plug out of the socket outlet before doing any work on the machine before changing the nozzle and wheneve...

Page 5: ...ere there could be a danger of explosion If any doubt arises please contact our authorized distributor It is not allowed to clean asbestos containing surfaces with high pressure This machine must not...

Page 6: ...sed flow The wide spray setting is useful for removing dirt from large areas washing cars etc Attaching the Foam Nozzle Fig 12 1 Fill the foam nozzle container with manufacturer recommended detergent...

Page 7: ...pressure switch may result WARNING Confirm that the nozzle is free of debris by removing it from the spray handle and visually inspecting inside the opening Always clean the nozzle opening after remo...

Page 8: ...seals are worn The filter is clogged Change the nozzle Check clean exchange Check and or exchange Check and or exchange Check and or clean There is excess noise Air is being drawn in The valves are w...

Page 9: ...t saat ini RCD Level Keamanan Produk IPX5 P e r a t u r a n K e s e l a m a t a n U m u m d a n Pencegahan Kecelakaan Ini Penting bahwa Anda membaca peraturan keselamatan dan instruksi pengoperasian s...

Page 10: ...dengan tekanan tinggi Mesin ini tidak boleh digunakan pada suhu dibawah 0 C Sambungan pasokan listrik misalnya koneksi kabel RCD atau memperbaiki dilakukan dengan kualifikasi dan mematuhi IEC60364 1 i...

Page 11: ...r yang disemprot menyebar berfungsi untuk menghilangkan kotoran di area yang luas mencuci mobil dll Pemasangan Deterjen Nozzle Gbr 12 1 Isi wadah nozzle sabun dengan sabun pencuci yang di rekomendasik...

Page 12: ...n dengan mengetuknya pada meja dan ujung noselnya ke bawah Jika nosel tersumbat tekanan air akan rendah dan mungkin akan menyebabkan kerusakan pada alat PERINGATAN pastikan bahwa nosel selalu dalam ke...

Page 13: ...tersumbat Katup seal aus Seal aus Filter tersumbat Gantikan nosel Cek bersihkan ganti Cek dan atau ganti Cek dan ganti Cek dan bersihkan Terlalu bising Angin tertarik ke dalam Katup aus kotor atau te...