2MA/2MB
1-4-14
2200
Drum motor error
The drum motor ready input is
not given for 5 s during the
drum motor is ON.
Defective connec-
tor cable or poor
contact in the con-
nector.
Reinsert the connector. Also check for conti-
nuity within the connector cable. If none,
replace the cable.
Drum motor and engine PWB (YC13)
Defective drive
transmission sys-
tem of the drum
motor.
Check if the rollers and gears rotate
smoothly. If not, grease the bushes and
gears. Check for broken gears and replace if
any.
Defective drum
motor.
Replace the drum motor.
Defective engine
PWB.
Replace the engine PWB and check for cor-
rect operation (see page 1-5-27).
2330
Fuser pressure release
motor error
When the fuser pressure
release motor is driven, the
motor over-current detection
signal is detected continu-
ously for 8 times (800 ms) at
100 ms intervals.
Defective connec-
tor cable or poor
contact in the con-
nector.
Reinsert the connector. Also check for conti-
nuity within the connector cable. If none,
replace the cable.
Fuser pressure release motor and engine
PWB (YC38)
Defective drive
transmission sys-
tem of the fuser
pressure release
motor.
Check if the rollers and gears rotate
smoothly. If not, grease the bushes and
gears. Check for broken gears and replace if
any.
Defective fuser
pressure release
motor.
Replace the fuser pressure release motor.
Defective engine
PWB.
Replace the engine PWB and check for cor-
rect operation (see page 1-5-27).
2340
Fuser pressure release
motor time-out error
When the fuser pressure
release motor is driven, the
envelope switch (EVSW) is
not detectable for 6 s.
Defective connec-
tor cable or poor
contact in the con-
nector.
Reinsert the connector. Also check for conti-
nuity within the connector cable. If none,
replace the cable.
Fuser pressure release motor and engine
PWB (YC38)
Defective drive
transmission sys-
tem of the fuser
pressure release
motor.
Check if the rollers and gears rotate
smoothly. If not, grease the bushes and
gears. Check for broken gears and replace if
any.
Defective fuser
pressure release
motor.
Replace the fuser pressure release motor.
Defective engine
PWB.
Replace the engine PWB and check for cor-
rect operation (see page 1-5-27).
Code
Contents
Causes
Check procedures/
corrective measures
Summary of Contents for FS-C2026MFP
Page 1: ...SERVICE MANUAL Published in December 2012 842MB113 2MBSM063 Rev 3 FS C2026MFP FS C2126MFP...
Page 4: ...This page is intentionally left blank...
Page 10: ...This page is intentionally left blank...
Page 38: ...2MA 2MB 1 2 14 This page is intentionally left blank...
Page 162: ...2MA 2MB 1 4 52 This page is intentionally left blank...
Page 213: ...2MA 2MB 1 5 51 9 Remove the scanner unit Figure 1 5 78 Scanner unit...
Page 225: ...2MA 2MB 1 5 63 4 Remove the paper conveying unit Figure 1 5 97 Paper conveying unit 1 2 2...
Page 230: ...2MA 2MB 1 5 68 This page is intentionally left blank...
Page 273: ...2MA 2MB 2 2 10 This page is intentionally left blank...
Page 299: ...2MA 2MB 2 3 26 This page is intentionally left blank...