2PG/2PH
1-5-29
1-5-9 Others
(1) Detaching and refitting the main motor
Procedure
1. Remove the right cover (See page 1-5-4).
2. Remove the connector.
Figure 1-5-40
3. Remove the M3 screw and two M4 screws.
4. Remove the main motor.
5. Check or replace the main motor and refit all
the removed parts.
Figure 1-5-41
Connector
Main motor
M3 Screw
M4 screws