P.27/51
FUEL OUTPUT PRESSURE INSPECTION
1. Turn the key to the OFF position.
2. Use the fuel hose clamp.
3. Disconnect the fuel hose from the fuel injector.
4. Connect the fuel pressure gauge.
5. Turn the key to the ON position.
5. Check the fuel pressure.
Standard:3.0 Bar
Caution
!
If the fuel output pressure is less than
3.0 bar, may fail to start the engine or in
trouble in case of riding.