KYLAND SICOM3000S Hardware Installation Manual Download Page 20

 

Connection

 

 

 

 

PGND 

PGND 

-/N 

PWR2

PWR2

+/L 

PWR2

PWR2

  Wiring and Mounting 

Step 1: Ground the device properly according to section 4.5.   

Step 2: Remove the power terminal block from the device.   

Step 3: Insert the power wires into the power terminal block according to Table 6 and fix 

the wires. 

Step 4: Insert the terminal block with the connected wires into the terminal block socket 

on the device.   

Step 5: Connect the other end of the power wires to the external power supply system 

according  to  the  power  supply  requirements  of  the  device.  View  the  status  of  the  power                         

LEDs on the front panel. If the LEDs are on, the power is connected correctly. 

Wiring and mounting should meet the following specifications   

Table 7 Wiring and Mounting Specifications 

Terminal Block type 

Torque requirements 

Cross-sectional area (AWG) 

Plug-in Terminal Block

 

4.5-5.0 lb-in 

12-24 

 

 

Caution:   

  Before connecting the device to power supply, make sure that the power input meets the power 

requirement. 

 

  To meet the UL requirements, the power supply of the device should conform the Class 2.

   

 

Warning:   

  Do not touch any exposed conducting wire, terminal or component with a voltage warning sign, 

it may cause damage to humans.   

  Do not remove any part or plug in or out any connector when the device is powered on.   

Summary of Contents for SICOM3000S

Page 1: ...SICOM3000S Industrial Ethernet Switch Hardware Installation Manual Publication Date May 2021 Version V1 1 No 112020193...

Page 2: ...ated as possible This document is not guaranteed to be error free and we reserve the right to amend it without notice to users All rights reserved No part of this documentation may be excerpted reprod...

Page 3: ...ls on the device or cables Ensure adequate heat dissipation and tidy cable layout without knots Wear antistatic gloves or take other protective measures when operating the device Avoid any exposed met...

Page 4: ...bstitute Do not purchase parts from other channels Dispose of the device in accordance with relevant national provisions preventing environmental pollution In the following cases please immediately sh...

Page 5: ...000Base T X ethernet port 12 4 2 POE Function 13 4 3 1000Base X 10 100 1000Base T X SFP interface 14 4 3 1 SFP optical module 15 4 4 Console Port 16 4 4 1 RJ45 Console Port 16 4 5 Grounding 17 4 6 Pow...

Page 6: ...8 Basic Features and Specifications 29...

Page 7: ...EE802 3af The switch can provide a maximum of 240W L16 power The specific configuration is as follows Table 1 SICOM3000S Configuration Table Model number SICOM3000S 4GX8GP L16 L16 SICOM3000S 4GX8P L16...

Page 8: ...LED 2 PWR 2 LED 3 Run LED 4 Ring status LED 5 Reset button 6 Alarm LED 7 1000M SFP interface 8 1000M SFP interface speed LED yellow 9 1000M SFP interface link status LED green 10 1000M SFP interface...

Page 9: ...Structure and Interface 15 output signal LED 16 input signal LED 17 POE output LED 18 output signal interface 19 output GND 20 input signal interface 21 input GND 2 2 Top Panel Figure 2 Top panel...

Page 10: ...are only for reference 3 2 Mounting Modes and Steps The switch supports DIN rail mounting Before installation make sure that the following requirements are met 1 Environment temperature 40 to 85 ambie...

Page 11: ...tch and ensure enough space and smooth heat dissipation Step 2 Clamp the top of the rail seat on the DIN rail slightly force up the bottom of the device rotate the device follow arrow 2 as below figur...

Page 12: ...Mounting Figure 5 DIN rail dismounting...

Page 13: ...network device with a straight through or cross over cable Pin Definition Figure 6 RJ45 PIN number Table 2 10 100Base T X Ethernet Port PIN Definition PIN MDI X signal name MDI signal name 1 Receive...

Page 14: ...Base T X ethernet interface as PSE Power Sourcing Equipment 10 100Base T X and 10 100 1000Base T X ethernet port support IEEE802 3at compatible IEEE802 3af each POE port supplies up 30W power L16 L16...

Page 15: ...e Data TRD1 V 7 Transmit Receive Data TRD2 Transmit Receive Data TRD3 8 Transmit Receive Data TRD2 Transmit Receive Data TRD3 Note and indicate level polarities 4 3 1000Base X 10 100 1000Base T X SFP...

Page 16: ...4 3 1 SFP optical module Figure 8 SFP optical module SFP optical module interface adopts standard LC fiber connector each interface is divided into transmit port TX port and receive port RX port To e...

Page 17: ...d RX ports In this case swap the two connectors at one end of the fibers Caution The device uses laser to transmit signals over fiber The laser meets the requirements of level 1 laser products Do not...

Page 18: ...le Cable Table 5 Pin Definitions of DB9 Port 9 Pin Serial Port and RJ45 Port Console Port DB9 Port 9 Pin Serial Port RJ45 Port Console Port Pin Signal Pin Signal 2 RXD Receive Data 2 TXD Transmit Data...

Page 19: ...he device This device supports redundant power input and adopts 5 core 5 08 mm spacing plug in terminal block when any one of the power supply failure the device can run normally without interruption...

Page 20: ...e View the status of the power LEDs on the front panel If the LEDs are on the power is connected correctly Wiring and mounting should meet the following specifications Table 7 Wiring and Mounting Spec...

Page 21: ...k Socket Electrical parameters of relay Maximum voltage 250VAC 220VDC Maximum current 2A Maximum power 60W Maximum insulation withstand voltage 2KV Note Pin 1 and Pin 2 is a normally open contact Pin...

Page 22: ...nt panel which provides two low drive input signal acquisition high drive output ability the input is optocoupler isolated acquisition and the output is normally open and normally close output When de...

Page 23: ...ess the reset button 0 5 3 seconds then release to complete the device restart Press the reset button continuously for more than 3 seconds then release to restore the default configuration and restart...

Page 24: ...DRP mode Blinking Slave DT Ring mode B Root or Normal DRP mode OFF Non ring mode Alarm LED ON Alarm OFF No alarm 1000M SFP speed status LED Yellow ON 1000M working status 100Base X OFF No connection...

Page 25: ...OFF 10 100M working mode or no connection 10 100 1000Base T X Ethernet port link status LED Green ON The valid network connection is established Blinking Network activity OFF The valid network connect...

Page 26: ...t of a PC with the delivered DB9 RJ45 console cable Step 2 Open Hyper Terminal in Windows OS On the Windows desktop click Start All Programs Accessories Communications Hyper Terminal Step 3 Create a n...

Page 27: ...ardware Device Manager Port to view the communication port Step 5 Set port parameters Bits per second 115200 Data bits 8 Parity None Stop bits 1 and Flow control None as shown in the below figure Figu...

Page 28: ...figuration Mode 7 2 Access through Telnet Step 1 Connect the network port of the PC to the Ethernet port of the switch with a network cable Step 2 On the Windows desktop click Start and Run Enter teln...

Page 29: ...of the browser You can log in to the Web management interface by using default user name admin and password 123 Note IE8 0 or above version is recommended For details about how to access the switch an...

Page 30: ...2 3at Terminal Block L16 5 pin 5 08mm spacing plug in terminal block Rated Power Consumption Rated power consumption 15W no PoE Physical Housing Metal no fan IP level IP40 Mounting DIN rail mounting D...