Page 1: ... Industrial Ethernet Switch Hardware Installation Manual Kyland Technology Co Ltd Publication Date Mar 2013 Version V1 0 FAX 86 10 88796678 Website http www kyland com E mail support kyland com No 1 12 02 1046 0 ...

Page 2: ...ated as possible This document is not guaranteed to be error free and we reserve the right to amend it without notice to users All rights reserved No part of this documentation may be excerpted reproduced translated annotated or duplicated in any form or by any means without the prior written permission of KYLAND Corporation Copyright 2013 Kyland Technology Co Ltd ...

Page 3: ...e other protective measures when operating the device Avoid any exposed metal wires because they may be oxidized or electrified Install the device in accordance with related national and local regulations Before power on make sure the power supply is within the allowed range of the device High voltage may damage the device Power connectors and other connectors should be firmly interconnected Do no...

Page 4: ...ntal pollution In the following cases please immediately shut down your power supply and contact your Kyland representative Water gets into the equipment Equipment damage or shell damage Equipment operation or performance has abnormally changed The equipment emits odor smoke or abnormal noise ...

Page 5: ... Connection 8 4 1 10 100Base T X Ethernet Port 8 4 1 1Functions 8 4 1 2Pin Definitions and Wiring Sequence 8 4 2 10 100 1000Base T X Ethernet Port 10 4 3 1000Base X 10 100 1000Base T X SFP Slot 11 4 3 1Gigabit SFP Optical Module 12 4 3 2Gigabit SFP Electrical Module 13 4 4 1000Base X 10 100 1000Base T X Combo Port 13 4 5 Grounding 14 4 6 Power Terminal Block 15 5 LEDs 17 6 Basic Features and Speci...

Page 6: ...n The series switches support DIN rail and panel mounting KIEN2204S provides two 1000Base X 10 100 1000Base T X Combo ports Combo ports and four 10 100Base T X Ethernet ports The four 10 100Base T X Ethernet ports support 802 3at POE output Each POE port provides 30W feed 44 57VDC Table 1 KIEN2204S Model Model Port Power Supply Combo port 10 100Base T X Ethernet port 802 3at KIEN2204S 2GX GE 4T 4P...

Page 7: ...scription of the Front Panel of KIEN2204S No Identifier Description 1 PWR1 Power 1 LED 2 PWR2 Power 2 LED 3 Alarm Alarm LED for future release 4 GX1 GX2 Gigabit SFP slot connection status LEDs 5 GX1 GX2 Two gigabit SFP slots 6 GE1 GE2 Two 10 100 1000Base T X Ethernet ports 7 10 100 1000Base T X Ethernet port speed LED yellow 8 10 100 1000Base T X Ethernet port connection status LED green 9 GX1 GE1...

Page 8: ...ase T X Ethernet port speed LED yellow 13 10 100Base T X Ethernet port connection status LED green 14 POE 1 4 POE LED 2 2 Top Panel Figure 2 Top Panel of KIEN2204S Table 3 Description of the Top Panel of KIEN2204S No Identifier Description 1 Power terminal block 2 Grounding screw ...

Page 9: ...e use caution when coming in contact and avoid covering the switch housing when the switch is running 3 2 Mounting Modes and Steps The series switches support DIN rail and panel mounting Before installation make sure that the following requirements are met 1 Environment temperature 40 to 85 ambient relative humidity 5 to 95 non condensing 2 Power requirement The power input is within the voltage r...

Page 10: ...at Make sure the device is firmly installed on the DIN rail as shown in the following figure Figure 5 DIN Rail Mounting Dismounting Step 1 Insert the head of a screwdriver into the opening of the spring locking piece at the bottom from the left Lift the handle of the screwdriver to open the spring locking piece of the connecting seat as shown on the left of the following figure Step 2 Move the dev...

Page 11: ...35mm 137mm Step 3 Punch four holes in the selected position according to the dimensions for panel mounting Insert four screws into the four holes respectively and turn the screws with a screwdriver until about a 5mm distance is left between each screw head and the wall Step 4 Align the four mounting holes on the plate for panel mounting with the four screws Insert the screws through the Ф6 5 posit...

Page 12: ... figure Then remove the plate for panel mounting from the four screws to detach the device from the wall or inner wall of the cabinet Step 2 Loosen the screws completely with a screwdriver Remove them from the wall or inner wall of the cabinet Then remove the plate for panel mounting from the rear panel to complete dismounting the device Figure 8 Panel Dismounting ...

Page 13: ...s of KIEN2204S support 802 3at POE output Serving as the Power Sourcing Equipment PSE KIEN2204S can provide power supply for PDs through 10 100Base T X Ethernet ports Each POE port provides 30W feed 44 57VDC 1 POE Definition POE indicates that the device can provide power supply for PDs through Ethernet ports The device allows a maximum distance of 100m for power supply 2 POE Power Supply The devi...

Page 14: ...TD Receive Data RD V 4 Unused Unused V 5 Unused Unused V 7 Unused Unused V 8 Unused Unused V Note and indicate level polarities 1 2 3 and 6 are data wires 4 5 7 and 8 are free wires Both types of wires are used for PD power supply at the same time Wiring Sequence Figure 10 Connection Using Straight through Cross over Cable Note The color of the cable for RJ45 connector meets the 568B standard 1 or...

Page 15: ...e T X RJ45 port 8 7 6 5 4 3 2 1 Figure 11 RJ45 Port The following table lists the pin definitions of the 10 100 1000Base T X RJ45 port Table 5 Pin Definitions of 10 100 1000Base T X RJ45 Port Pin MDI MDI X 1 Transmit Receive Data TRD0 Transmit Receive Data TRD1 2 Transmit Receive Data TRD0 Transmit Receive Data TRD1 3 Transmit Receive Data TRD1 Transmit Receive Data TRD0 4 Transmit Receive Data TR...

Page 16: ... requires an SFP optical electrical module to enable data transmission The following table lists the gigabit SFP optical electrical modules optional supported by KIEN2204S Table 6 Gigabit SFP Optical Electrical Modules Model Port MM SM Connector Central Wavelength Transmission Distance IGSFP M SX LC 850 0 55 1000Base X port MM LC 850nm 0 55km IGSFP S LX LC 1310 10 1000Base X port SM LC 1310nm 10km...

Page 17: ...How to Connect the SFP Optical Module Insert the SFP optical module into the SFP slot in the switch and then insert the fibers into the TX port and RX port of the SFP module Figure 15 Connecting the SFP Optical Module Identify the RX port and TX port of an SFP optical module 1 Insert the two connectors in one end of two fibers into the SFP module and those in the other end into the peer module 2 V...

Page 18: ...ule into the SFP slot in the switch and then insert the RJ45 connector of the twisted pair into the SFP module Figure 17 Connecting the SFP Electrical Module 4 4 1000Base X 10 100 1000Base T X Combo Port 1000Base X 10 100 1000Base T X Combo port Combo port for short consists of one gigabit SFP slot and one 10 100 1000Base T X Ethernet port Only one of the two can work at a time The gigabit SFP slo...

Page 19: ...efore you must ground the switch properly You need to ground the switch before it is powered on and disconnect the grounding cable after the switch is powered off The switch provides a grounding screw on the top panel for chassis grounding After crimping one end of the grounding cable to a cold pressed terminal secure the end to the grounding screw and connect the other end to the earth firmly Fig...

Page 20: ...erminal Block The following figure shows the 5 pin 5 08mm spacing plug in terminal block Figure 19 5 Pin 5 08mm Spacing Plug in Terminal Block socket The following table lists the pin definitions of the 5 pin 5 08mm spacing plug in terminal block Table 8 Pin Definitions of 5 Pin 5 08mm Spacing Plug in Terminal Block No DC Definition AC Definition 1 PWR1 PWR1 L 2 PWR1 PWR1 N 3 PGND PGND 4 PWR2 PWR2...

Page 21: ...f 5 Pin 5 08mm Spacing Plug in Terminal Block Caution The switch supports 48DC power input Before connecting the device to power supply make sure that the power input meets the power requirement If connected to an incorrect power input the device may be damaged Warning Do not touch any exposed conducting wire terminal block or component with a voltage warning sign because it may cause damage to hu...

Page 22: ...nking The POE port provides power supply abnormally Off The POE port provides no power supply 10 100Base T X Ethernet port speed LED yellow On 100M working state 100Base TX Off 10M working state 10Base T or no connection 10 100Base T X Ethernet port connection status LED green On Effective port connection Blinking Ongoing network activities Off No effective port connection 10 100 1000Base T X Ethe...

Page 23: ...tion no PD 6W MAX Physical Characteristics Housing Aluminum fanless Installation DIN rail and panel mounting Dimensions W H D 88mm 135mm 137mm excluding connectors DIN rail and plate for panel mounting Weight 1 25Kg Environmental Limits Operating temperature 40 85 Storage temperature 40 85 Ambient relative humidity 5 95 non condensing MTBF MTBF 326 200 hours Warranty Warranty 5 years For more info...