KYL KYL-300H Manual Download Page 7

Shenzhen KYL Communication Equipment Co., Ltd

Fax: +86-755-82943662                  [email protected]                   

www.rf-data.com

7

Timing diagram:

c. Error dealing procedure:

To enhance the reliability and stability of user’s systems, a verify bit or a Cyclic 
Redundancy Check (CRC) mode is highly recommended to resent the wrong 
information while using KYL-300H modules.

d. Large-number data transmission

In theory, when the interface data rate is faster than the RF data rate, KYL-300H
transceivers can sent unlimited-long data package, but any long packages more than 
120B are not recommended. The length of each package should be between 60~100B. 
We also recommend user to resent the wrong information using Automatic Error 
Request Equipment (ARQ).

The analyzing as below:

What if the actual transmission BER (Bit Error Rate) is 10

-4

, 1 packet with 1KB data, 

which is about 10-thousand bits, is sent, theoretically, at least 1 bit will be received 
wrongly, then the 1KB information will never be received correctly.   
But if we package the data into 10 packets with 100B for each, when all 10 packets 
are sent, there will be only 1 packet wrong according to this probability. After that, 
resend this wrong packet using ARQ mode. So by resending one more packet and the 
efficiency rate is reduced 10%, all data will be absolutely received correctly.

9. Antenna configuration:

Many appropriative antennas for low power RF modules are selected for meeting 
different user antenna configurations. Please ask our Sales office for further 
information about the antenna’s dimension and performance.

a. 

Helical SMA antennas

KYL-ANT-433-10-SMA: 100mm helical SMA antennas with high gain and low cost, 
reach a long distance.

Summary of Contents for KYL-300H

Page 1: ...Shenzhen KYL Communication Equipment Co Ltd Address C3705 3707 Huangdu Square South of Exhibition Center Yitian Road Futian District Shenzhen Guangdong China 518048 Tel 86 755 82943662 Fax 86 755 834...

Page 2: ...KYL 300H provides 8 channels expandable for 16 32 channels according to requirements of users 7 2 ports with three connection methods KYL 300H transceivers provide 2 ports with three connections a UAR...

Page 3: ...ote controller Data communication in the aspects of railway oil field dock and army LED display in thruway and public place Point to multi point wireless network wireless on the spot bus and automatic...

Page 4: ...ata input to the transceiver TTL TxD 4 TxD TTL Transmitted data out of the transceiver TTL RxD 5 SGND Signal 6 A TXD A of RS 485 TxD of RS 232 A RxD 7 B RXD B of RS 485 RxD of RS 232 B TxD 8 SLEEP Sle...

Page 5: ...e the workload of terminal CPU we can add other specific functions based on the transparent protocol such as addressing data acquisition command interpretation etc 7 Sleep function instruction Due to...

Page 6: ...e first bit received by RxD Due to a data processing will be made on user s data by KYL 300H transceiver using FEC Forward Error Correction or other correction algorithm when RxD of a KYL 300H transce...

Page 7: ...as below What if the actual transmission BER Bit Error Rate is 10 4 1 packet with 1KB data which is about 10 thousand bits is sent theoretically at least 1 bit will be received wrongly then the 1KB in...

Page 8: ...te http www rf data com Products_list_en asp classid 163 If you have special demands on antennas please specify we can design and produce for you individually IV Network Application of KYL 300H The co...

Page 9: ...r the programming of serial port all you have to do is to remember that its communication mode is semi duplex while always observing the time sequence of come and go for receiving and transmitting V T...