Parameter setting or reading as per the testing software KYLPRO.exe in the PC (in 
products box).And the configuration is as follows:

i. Channel configuration:

Channel No.

Frequency

Channel No.

Frequency

1

429.0325MHZ

5

433.0325MHZ

2

430.0325MHZ

6

434.0325MHZ

3

431.0325MHZ

7

435.0325MHZ

4

432.0325MHZ

8

436.0325MHZ

Note: the frequency points corresponding to each channel can be adjusted based on the 

user’s needs.

5. The Function-indicator light

a. The LED indicator light will glitter red for 0.5S once after switched on.
b. The LED indicator light will glitter green continually while receiving data from air.
c. The LED indicator light will glitter red continuously when transmitting data into air 

after receiving from COM.

d. If the module enables the sleep function, LED indicator light is always dark.

6. Supported protocol and Transmit capability

KYL-300H standard transceivers offer transparent protocol to support various 
applications and protocols of users. If the user needs to decrease his cost or ease the 
workload of terminal CPU, we can add other specific functions based on the transparent 
protocol, such as addressing, data acquisition, command interpretation, etc.

7. Sleep function instruction:

Due to reducing more consumption, KYL-300H transceivers support Sleep function. In 
sleep mode, the current consumption is less than 1mA.

a. How to use the Sleep function:

The Pin8 ‘SLP’ in JP1 is the signal of sleep control. In high power level, transceiver
stays in working mode. In low power level (<0.5V), transceiver stays in sleep mode. 
The SLP signal can convert transceiver from working to sleep mode in 1ms after 
falling edge. If the Sleep signal arrives when the transceiver is transmitting data, the 
module will enter sleep mode after finishing transmission. From sleep mode to
working, it takes the transceiver 1ms after rising edge.
To disable the opened sleep function of KYL-300H, the SLP (SLEEP) pin should be 
definitely connected with 0 or ground.

b. Attentions about use of sleep function:

When the sleep function enabled, any supply glitches, such as switch dithering, fire 
striking or quick switching on and off, could cause the transceiver to be switched to 
the wrong sleep mode.
After switching on, users can avoid this error by making a compulsive restoration 
once after the CPU delays 100ms.

Sleep Timing Diagram:

Summary of Contents for KYL-300H

Page 1: ...Shenzhen KYL Communication Equipment Co Ltd Address C3705 3707 Huangdu Square South of Exhibition Center Yitian Road Futian District Shenzhen Guangdong China 518048 Tel 86 755 82943662 Fax 86 755 834...

Page 2: ...KYL 300H provides 8 channels expandable for 16 32 channels according to requirements of users 7 2 ports with three connection methods KYL 300H transceivers provide 2 ports with three connections a UAR...

Page 3: ...ote controller Data communication in the aspects of railway oil field dock and army LED display in thruway and public place Point to multi point wireless network wireless on the spot bus and automatic...

Page 4: ...ata input to the transceiver TTL TxD 4 TxD TTL Transmitted data out of the transceiver TTL RxD 5 SGND Signal 6 A TXD A of RS 485 TxD of RS 232 A RxD 7 B RXD B of RS 485 RxD of RS 232 B TxD 8 SLEEP Sle...

Page 5: ...e the workload of terminal CPU we can add other specific functions based on the transparent protocol such as addressing data acquisition command interpretation etc 7 Sleep function instruction Due to...

Page 6: ...e first bit received by RxD Due to a data processing will be made on user s data by KYL 300H transceiver using FEC Forward Error Correction or other correction algorithm when RxD of a KYL 300H transce...

Page 7: ...as below What if the actual transmission BER Bit Error Rate is 10 4 1 packet with 1KB data which is about 10 thousand bits is sent theoretically at least 1 bit will be received wrongly then the 1KB in...

Page 8: ...te http www rf data com Products_list_en asp classid 163 If you have special demands on antennas please specify we can design and produce for you individually IV Network Application of KYL 300H The co...

Page 9: ...r the programming of serial port all you have to do is to remember that its communication mode is semi duplex while always observing the time sequence of come and go for receiving and transmitting V T...

Reviews: