background image

 

 

TYPE 9112-HEU 

     07/2014 

 
 

Dear customer, 

Thank  you  for  purchasing  of  the  appliance  KVS  MORAVIA  -  solid  fuel  range  cooker  with  heat 
exchange unit for connection to central heating hot water system. We trust that our product serves 
you  well.  Some  important  principles  should  be  observed

 

during  its  operation.  Therefore,  in  your 

interest, carefully study this manual and operate the product according to the given instructions. 
The 9112 appliance has a manufacturer issued declaration of conformity according to Section 12, 
Article 3, of Law No. 22/1997 of the Czech Republic.   

 

 

No  flammable  liquids  should  be  used  when  lighting  the  fire,  nor  should  they  be  used  to 
increase the nominal output of the appliance. 

 

The  appliance  should  not  be  used  for  waste  incineration;  only  recommended  fuels  may  be 
used. 

 

During operation, the ash tray door should be closed, and the fire door should only be opened 
for lighting the fire or raking the grate in order to prevent flue gas bleeding. 

 

The cooker cannot be used unless it is connected to a functioning water system even 
during the summer months, otherwise the heat exchanger will be overheated and thus 
suffer permanent damage.

 

 

Ash  should  be  put  into  non-flammable  ash  bins  with  covers!  Be  very  careful  during  the 
removal of hot ash. 

 

Pay attention to fire safety!  

 

It is forbidden to use the appliance if it is damaged (unfit for its function)! 

 

Any  contravention  of  the  operating  conditions  may  cause  damage  to  some  parts  of  the 
appliance. It is recommended not to overload the appliance in any way. If the temperature in 
the oven exceeds 300°C the thermometer function could be damaged. 

 

Possible noisy impacts (popping) of the metal plates or chipping of the fired clay lining 
inside the appliance are not subject to repair or a claim procedure. The cause of these 
impacts is the internal stress of the metal plates, which will fade after a certain time (it 
depends on the firing frequency). These occurrences endanger neither the safety, nor 
the function of the appliance. 

 

Any  repair  of  the  appliance,  except  cleaning  and  fired  claying  must  only  be  made  by  an 
authorised worker. 

 

Local  regulations,  including  those  regulations  related  to  national  and  European  standards, 
shall be observed during the installation of the appliance. 

 

It is recommended that you only use spare parts approved by the manufacturer.  

 

Unauthorised modifications of the appliance are forbidden. 

 

The appliance must only be operated by adults, and during operation, the appliance requires 
intermittent attendance and supervision. 

 

The appliance should be installed by an authorised specialist. No claims are accepted 

in case of incorrect or amateur installation. 

 
 
 

Important Information, Binding Instructions and Recommendations 

 

OPERATION & MAINTENANCE MANUAL

 

Summary of Contents for 9112-HEU

Page 1: ...TYPE 9112 HEU 07 2014 TYPE 9112 HEU OPERATION MAINTENANCE MANUAL INSTALLATION MANUAL SOLID FUEL RANGE COOKER WITH HOT WATER HEATER...

Page 2: ...for contact with foodstuff under all normal conditions or by the stated use of the manufacturer comply with the requirements of Law No 258 2000 Coll the Ministry of Health Decree No 38 2001 Coll and R...

Page 3: ...ntion to fire safety It is forbidden to use the appliance if it is damaged unfit for its function Any contravention of the operating conditions may cause damage to some parts of the appliance It is re...

Page 4: ...o the water to the water range 5 5 kW 3 5 kW Efficiency at NHO 75 Average temperature of flue gas at NHO 190 C Mass flow rate of flue gas at NHO 12 g s Minimum chimney draught 12 Pa Height of the work...

Page 5: ...Storage Drawer 2 Hob Top Plate II 8 Thermometer 3 Oven Door 9 Ash chamber Door 4 Combustion chamber Fire box Door 10 Grate bar 5 Hand Rail 11 Smoke Flap Control 6 Sweeping Door 12 Combustion Air Intak...

Page 6: ...control of air to the combustion chamber and thus alters the speed of fuel combustion energy output of the appliance The secondary combustion air supply can be controlled by means of a lever on the f...

Page 7: ...p panel 3 The single piece glass and ceramic panel You should always use pots with flat bases Drawing 2 Ignition Flap Drawing 3 Is placed below the range and controlled by means of the lever located a...

Page 8: ...utes and perform grating at the same time the combustion performance will improve The appliance output can be controlled by the supply of air under the grate and by the amount and type of fuel When op...

Page 9: ...rinks and 48 hours for food of solid or pasty consistence The Heat Exchange Unit The range cooker with built in heat exchange unit demands more user attention than a standard cooker or a typical boile...

Page 10: ...ng that individual parts fit tightly and seal perfectly Outer surfaces cleaning Clean the appliance after cooling Enamelled surfaces should be cleaned with a damp cloth or sponge and then polished to...

Page 11: ...anufacturer reserves the right to carry out small changes resulting from innovative or technical changes of the product that will have no detrimental affect on the function of the appliance 1 Producti...

Page 12: ...hrough the hob top it is necessary to remove the blanking cap and to attach the flue branch without the ring and use the delivered blank cover to close the rear outlet A chimney with a sufficient drau...

Page 13: ...tive baffle plate shall overlap the protected material up to the nearest wall ceiling made of a fireproof material however not less than 300 mm at the upper side and 150 mm at the lateral sides We rec...

Page 14: ...o use the connection with an open expansion tank in case of some air vaporization from the exchanger If the connection with the expansiomate is used it is necessary to mount a safety valve of 1 8 bar...

Page 15: ...TYPE 9112 HEU 07 2014 14 Dimensional Sketch of the appliance TYPE 9112 All of dimensions are in mm...

Page 16: ...TYPE 9112 HEU 07 2014 15 Installation schematic of the range cooker with a heat exchange unit within the interior of a domestic dwelling...

Page 17: ...TYPE 9112 HEU 07 2014 16 NOTE The valves a pump and other safety accessories are not supplied with the cooker...

Page 18: ...TYPE 9112 HEU 07 2014 17 Spare parts sketch part 1...

Page 19: ...TYPE 9112 HEU 07 2014 18 Spare parts sketch part 2...

Page 20: ...set 014 Ribbon 040 Chamotte lower panel 015 Plug plastic 041 Grate bearing 016 Ribbon 2 042 Rotatable grate 017 Cover strip 043 Grate bar 018 Oven door with frame 044 Frame set 018A Oven door frame 04...

Page 21: ...TYPE 9112 HEU 07 2014 20...

Page 22: ...112 HEU 07 2014 Producer KVS EKODIVIZE a s plant Dvorce Opavsk 272 793 68 Dvorce u Brunt lu CZECH REPUBLIC phone 420 554 797 111 fax 420 554 745 500 email prodej dvorce kvs ekodivize cz www kvs ekodiv...

Reviews: