MAX

6.

 Check the fi rmware version 

....

how to update the fi rmware  

To perform a fi rmware update

Make sure that the main menu is open.

Press U to update the USB fl ash drive.

Update Service with  kvm-tec Switching Manager Demoversion .... 

This is a comfortable update management for your switching system.

You can update all extenders at the same time. The update is performed in the background and in a second step the 

units are rebooting with the new fi rmware.

Only a short time is needed for the second step.

ATTENTION 

! Only when the bar is grey, the update is fi nished.

 

To view the fi rmware version

Make sure the 

main menu

 is open. The currently installed fi rmware version of the remote and local units are 

displayed (e.g. ‘4267’) and check that you have the same fi rmware on both units.

Ways to update  the fi rmware version 

....

There are four ways to perform an update:

UBS stick update 

Summary of Contents for MASTERflex

Page 1: ...Check out our Installation Channel www kvm tec com flex flex flex max kvm tec FIRST AID MAX ex Single redundant copper MAX ex Dual copper M MAY max max...

Page 2: ...t 4 DVI out to Monitor 3 Network cable CAT5e6 7 up to 150m 492ft main link 6 Audio from PC 7Audio to PC 7 Audio to speaker 6 Audio from microphone RS232 plug RS232 plug 1 Power plug 12V 1A redundant 1...

Page 3: ...tor 2 1 Power plug 12V 1A redundant 1 Power plug 12V 1A redundant Quick Installation MAX ex Dual local CPU remote CON 1 Connect the CON Remote and the CPU Local Unit to the included 12V 1A power suppl...

Page 4: ...orking Plug out in USB of keyboard and wait until driver is installed after few seconds Check all USB connections on both sides Local and Remote If it is still not working plug out in DC once more LED...

Page 5: ...plug ged in correctly Check if the PC is sending a Image by plugging in a monitor on the local out of the local Unit Check if the DDC is set correctly in menu under point O Check if both Units have th...

Page 6: ...rs at the same time The update is performed in the background and in a second step the units are rebooting with the new rmware Only a short time is needed for the second step ATTENTION Only when the b...

Page 7: ...cal and one remote at the same place connect the monitor directly to the PC does the monitor display an image follow the mentioned steps from above LED status is red or blinking this can be a cable pr...

Page 8: ...s Webcams Problem description Almost done If you want to be even faster on the phone the following data would be helpful No power No Link VGA problem No connection DOA dead on arrival Stripy screen No...

Page 9: ...e at any time This way the support team has all the infor mation about your system in a direct con versation and your advantage is that the questions can be answered in a targeted and faster way Probl...

Reviews: