79
Push buttons and rotary button usage
The terminal does not switch
off when connected to an
ISOBUS tractor.
The tractor does not switch off the
power from the ISOBUS in-cab connec-
tor.
Disconnect cable or
change tractor wiring to
switched power.
No implements are appear-
ing on the terminals.
Implement not or not correctly con-
nected.
Check if the ISOBUS cable
is properly connected to
the tractor.
Implement is defect.
Check if the implement is
working properly.
CAN bus termination has the wrong
setting.
Use the correct setting.
UT configuration
The touchscreen is not work-
ing.
The touchscreen is not calibrated.
Calibrate the touch-
screen.
touchscreen calibra-
tion
Pressure is applied to touchscreen or
surroundings (black border) by opera-
tor or objects.
Remove objects touching
the screen, so that no
pressure is applied to the
screen.
Failure
Possible cause