6.2 Technical data
In Table 4
below you will find the Kvaser USBcan Professional‘s technical specifications.
Table 4: Kvaser USBcan Professional Technical specifications.
CAN Channels
2 (CAN 2.0A and 2.0B active).
CAN Transceivers
SN 65251 (Compliant with ISO 11898-2)
CAN Controller
Built into the M32C
Microcontroller
Renesas M32C
CAN Bit Rate
5 kbit/s to 1 Mbit/s
Timestamp accuracy
2
μs
Error Frame Detection
Yes, both channels.
Error Frame Generation
Yes, when used as a USB-CAN interface.
PC interface
USB 2.0. Supports HiSpeed (HS) at 480 Mbit/s.Compatible with USB
1.1 at 12 Mbit/s.
Power consumption
~ 5V and 130mA when powered from the USB.
Software requirements
Windows XP or later. (For other operating systems, see Kvaser web or
contact Kvaser support.)
Hardware configuration
Done by software (Plug & Play).
Dimensions (W x L x H)
46 x 115 x 22 mm (1.8 x 4.5 x 0.9 inch)
Operating temperature
-40 ºC ... +85 ºC
Weight