6. Create a full size cyan circle (static tunnel effect) and check whether the green circle overlays the blue circle all the
way around the shape. If not, adjust the beam path of the green circle accordingly (step 2 on the diagram above).
7. Create a full size yellow circle (static tunnel effect) and check whether the red circle overlays the green circle all the
way around the shape. If not, adjust the beam path of the red circle accordingly (step 3 on the diagram above).
8. Create a full size red circle (static tunnel effect) and check whether the 2nd red circle overlays the 1st red circle all the
way around the shape. If not, adjust the beam path of the 2nd red circle accordingly (step 4 on the diagram above).
All alignment screws A,B,C and D must be fastened at the end of each beam alignment procedure. Even
if only one of them is loose, there will be not enough internal pressure on the pivoting bolt (E), which may
result into misalignment of respective colour.
!
Always loosen one of the screws in the pair first, before tightening the 2nd one down.
!
4. Power up the system as normal.
5. Firstly, it is necessary to align a colour with the longest beam path between the laser module output and the scanning
system in a way so it hits the exact centre of the bottom scanning mirror – in this case it is the blue laser beam.
Create a blue beam effect (point) and check visually whether the beam hits the exact centre of the bottom scanning
mirror. If not, follow the diagram below to adjust the beam path accordingly (step 1 on the diagram).