Beam Alignment
[CM-3400 FB4]
1. Loosen 2 silver bolts that hold the
in place on the side of the unit and remove the cover.
2. Create a full size red circle (static tunnel effect) and check whether the red circles of all R6, R5, R4, R3, R2 and R1
overlay each other all the way around the shape (step 1 on the diagram).
6.3
Although KVANT uses the latest technology to protect all the critical components inside this laser
system against Electrostatic Discharge, the semiconductor laser diodes within this system are extremely
vulnerable to it. This is due to some of the electronic components being exposed when the top cover is
taken off.
If you decide to proceed with the Beam Alignment process yourself, it is absolutely essential that all the
common ESD protection rules are strictly followed. We don’t accept any responsibility for Electrostatic
Discharge damages to laser diodes caused by customer.